Green BM200-32 Benutzerhandbuch - Seite 9
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Batterieladegerät Green BM200-32 herunter. Green BM200-32 19 Seiten. Battery tester charger discharge maintainer
After the battery is emptied, the display screen will There are two different display contents:
3.2V 100Ah LiFePO4
Discharged
from full
test Capacity
98.7 Ah
When discharge battery from full charged state, after
discharged empty, it will get an accurate capacity.
After the battery is fully charged, to view the charging curve of the battery, please press
<Up> Key, screen will display the complete battery charging curve, as follows:
Press <Up> or <Down> key again, you can switch the graph and list pages alternately
[Maint]: Automatic maintenance based on selected battery parameters:
4.4
For batteries that have been idle for more than 6 months or have been floating
charged for a long time, it should be regularly (preferably every 6 months or so)
standard charging and discharging maintenance process. The standard
maintenance procedure is to use 0.2C current first fully charge the battery - then
drain the battery with 0.1C current - then use 0.1C charge current to full fill the
battery. After finished this maintenance process, the vitality, the life time and the
effective capacity of battery will be protected and improved to the maximum.
SHENZHEN GREEN DIGITAL POWER TECH CO., LTD
SOC.
:
0%
SOH.
:
98.7%
RES.
:
5.2mΩ
:3h 43m
Time run
Discharg
:98.7Ah
discharge curve
voltage
3.2V 100Ah LiFePO4
SOC.
SOH.
Discharged
RES.
from non-full
est. Capacity
Time run
97.7 Ah
Discharg
When discharge battery from non-full state, after
discharged empty, it will get an estimated capacity.
time
:
0%
:
97.7%
:
5.2mΩ
:3h 43m
:67.6Ah