Green GPM-315 Handbuch

Blättern Sie online oder laden Sie pdf Handbuch für Messgeräte Green GPM-315 herunter. Green GPM-315 2 Seiten. Process value indicator

FRONT VIEW
V LOW ALM
LOW ALM
PASS
HIGH ALM
V HIGH ALM
SET
GREEN
GPM - 315
PROCESS VALUE INDICAT0R
75
BACK VIEW
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
105
Model
Range
Outputs
Output Voltage & Current
User Programming
Supply voltage
Operating voltage range
Power consumption ( Without Load )
Input Low Value
Input High Value
Alarm indication ( LOW, V LOW, PASS, HIGH & V HIGH )
Output Indication ( LOW, V LOW, PASS, HIGH & V HIGH )
Function
Mounting Cutout dimension
Weight
Dimension ( L x W x D )
Ambient humidity
Ambient temperature
Storage temperature
In the pack
DIMENSIONS
SIDE VIEW
75
48
10
75
PANEL CUTOUT
48
90
SPECIFICATIONS
GPM-315
9999 Counts
24 VDC Upto 50mA
3 Keys & LED Display
24 VDC
+ / -10% from the rated voltage
1.5 VA
0 for 0-10V, 0-20mA (or) 20 for 4-20mA
100 for 0-10V, 0-20mA & 4-20mA
Red LED
Red LED
Process Monitoring and Alarm
45 x 90 Cutout
170 grams
48 x 105 x 85
35 to 85 % RH
-10 to 55 c
-25 to 65 c
Process Indicator, 2 sets of Mouning Clamps with Screws & Inst., Manual
GPM-315
PROCESS VALUE INDICATOR
INTRODUCTION
45
Thank you very much for purchasing this product GPM-315.
Please read the instruction manual carefully for the full usage of
this product
This Product has passed various quality tests before despatch.
Please check however, at the time of arrival, its model code
and its appearance and ensure that all the contents are provided
and there are no faults, damage etc, to the module. Please also
ensure that the model code ,which is labeled on the module,
is identical to the one you ordered.
F
NOTE:
1. Our company shall not be liable for any damages, as described
below, caused to both any users and third parties
45
a) Damages caused by the result of operation of the product.
b) Damages caused by any defects in the product which are
unpredictable for us.
2. The content in this manual are subject to change without any
notice. If you have any suggestion on the matter,
Please do not hesitate to contact us.
All dimensions are in mm
FOR 0-10 VDC
0-10 VDC
Source
SELECTION
OPEN FOR
0-10 VDC
4
1
2
3
0 - 10
4 - 20
0 V
SELECTION
VDC
mA DC
V HIGH
ALM
9
10
11
12
SELECTION TERMINAL 4 & 5 :
OPEN - VOLTAGE SOURCE (0-10 VOLTS)
CLOSE - CURRENT SOURCE (4-20 A)
m
GREEN MICROELECTRONICS INDIA PVT. LTD.
green@green
PRECAUTION FOR SAFE USE
(1) Use and store the Product within the specified
ambient temperature and humidity ranges.
(2) Do not use the product in location subject to vibrations
or shocks. Using the product in such location over a long
period may result in damage due to stress.
(3) Do not use the product in locations subject to dust,
corrosive gases, or direct sunlight
(4) Separate the input signal devices, input signal cables
and the product from the source
cables producing noise
(5) The supplied power voltage and load must be within the
rated and specified ranges.
(6) Do not use where the water or oil splatter on the Product.
(7) Install a switch or circuit breaker that allows the operator
to immediately turn off the power
CIRCUIT DIAGRAM
FOR 4-20 mA
4-20 mA
Source
5
6
7
8
1
2
V LOW
LOW
PASS
0 - 10
4 - 20
ALM
ALM
VDC
mA DC
0 V
HIGH
COM.
24 VDC
ALM
FOR O/P
SUPPLY
9
13
14
15
16
10
SUPPLY
24 VDC
MANUFACTURER
electronics
.in
www.greenelectronics.in
of noise or high - tension
SELECTION
SHORT FOR
4-20 mA
3
4
5
6
7
8
0 V
V LOW
LOW
PASS
SELECTION
ALM
ALM
0 V
V HIGH
HIGH
COM.
24 VDC
FOR O/P
ALM
ALM
SUPPLY
11
12
13
14
15
16
SUPPLY
24 VDC
V2.1