Green Brook OD100 Schnellstart-Handbuch

Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Sicherheitssensoren Green Brook OD100 herunter. Green Brook OD100 2 Seiten. Infra-red motion detector - wall switch

Infra-red Motion Detector - Wall Switch
Please read these instructions carefully before installation and keep safe for future
reference.
IMPORTANT
This product should be installed by a competent person and in accordance with the
current IET Wiring Regulations and Building Regulations.
If in doubt,consult a qualified electrician.
Always turn off the mains supply before commencing work.
Not suitable for parallel connections
As the detector responds to changes in temperature, avoid the following situations:-
Avoid pointing the detector towards objects with highly reflective surfaces, such as
mirrors etc.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning
units, lights etc.
Avoid pointing the detector towards objects that may move in the wind, such as
curtains, tall plants etc.
Switch the mains supply OFF first to prevent electric shock.
1.
Unclip both face plates using a small
flat-blade screwdriver, refer to Dia:1.
Dia:1
'Orion Range'
Model: OD100
Important Safety Instructions
Model: OD100 -
Function Switch:
'ON'
'OFF'
'PIR"
FIELD OF DETECTION
INSTALLATION
= Permanently ON
= Permanently OFF
= PIR Control
2.
Connect the Live in wire to the 'L'
terminal and Load out wire to the 'A'
terminal, refer to Dia:2.
L
Dia:2