Green Brook OD105 Schnellstart-Handbuch - Seite 2

Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Sicherheitssensoren Green Brook OD105 herunter. Green Brook OD105 2 Seiten. Infra-red motion detector - ceiling mounted

2.
Connect wiring in accordance
with Dia:2.
3.
Fold the metal springs of the sensor upwards and insert into the installation hole releasing
springs, the springs will hold sensor in position.
4.
To access the lux and time controls, insert a small flat-bladed screwdriver into the open
release slot and twist, pull down until the controls are showing.
Note:
Please refer to Data Sheet on the GreenBrook website -
www.greenbrook.co.uk for wiring sensor in parallel.
1. Turn 'Time'control fully anti-clockwise and 'Lux' control fully clock wise refer to Dia:4.
Dia:4
2. Re-connect mains supply, allow 30 seconds for the sensor to warm-up, and then perform a
walk-by in front of the sensor; lamp should turn on and stay on for approximately 10
seconds,and will go off if no further movement is detected.
1. Turning Lux control fully clock wise, the sensor will operate in both daylight and darkness.
2. Turning Lux control fully anti-clockwise, the sensor will operate in darkness only.
3. Set control to operate at your required daylight level.
1.
Turning the time control fully anti-clock wise will set the on duration to 10 seconds +/- 3
seconds.
2.
Turning the time control fully clock wise will set the on duration to 15 minutes +/- 2 minutes.
Light not coming on
Check that lamp is good.
Check there is nothing obscuring the PIR sensor.
Intermittent operation
Check there are no curtains that can move in the wind.
Check there are no heating vents nearby.
NOTE:
Product & Packaging Disposal
When disposing of this item and its packaging
please follow local regulations and use an
appropriate waste disposal centre.
See GreenBrook website for further details.
Dia:2
ADJUSTING THE 'LUX' CONTROL
ADJUSTING THE 'TIME ON' CONTROL
TROUBLE SHOOTING
TECHNICAL INFORMATION
Rated Voltage:
IP Rating:
Ambient Light:
Time Delay:
Rated Load:
Detection Range:
Detection Distance:
Working Temp:
Working Humidity:
Power Consumption:
Installation Height:
Cut Out:
Detection Moving Speed: 0.6 - 1.5m/s
Dimensions:
Total Depth -
Ceiling Protrusion -
Conforms To:
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
www.greenbrook.co.uk
TESTING
230V~50Hz
IP20
<3-2,000 LUX (Adj)
Min 10 sec ± 3 sec
Max 15 min ± 2 min
Max 800W
Max 400W
360°
6M max (<24°C)
-20° - + 40°C
<93%RH
0.5W approx
2.2 - 4M
65mm
80Ømm
71.1mm
18.3mm
BS EN61058-1
Your GreenBrook Motion Detector Ceiling
Mounted OD105 is guaranteed for 1 year
from the date of purchase.
This is in addition to your statutory rights.
N
/ LED
GUARANTEE
L
L