KitchenAid GSU-42-E-2 Installationsanleitung Handbuch - Seite 6

Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Kochfeld KitchenAid GSU-42-E-2 herunter. KitchenAid GSU-42-E-2 8 Seiten. 42" gas cooktop with broiler/griddle

Check
air shutter
setting.
On natural
and LP gas there
should
be
a 3/4"
slot in burner
at both
top and bottom.
%
The
unit
is now ready
to plug service
cord
into
receptacle.
Make
sure
that
power
supply
neutral
is connected
to the wide
blade
slot
in receptacle.
It
is essential
that
the
electrical
outlet
to
which
the plug is connected
be properly
grounded
and polarized.
If this
is in doubt,
a qualified
electrician
should
be contacted
to
check
the outlet.
Initial
checks
are
made
either
with
or without
cooktop
de-
pending
upon
whether
or not the unit was converted
for LP gas,
1" OPENING
-\
TOP AND
BOTTOM
Test
each
top
burner
one at a time
by setting
knob
to "light"
position.
This
is done
by pushing
in on knob
and turning
knob
to left or counterclockwise.
Repeat
at least
four
times.
A clicking
sound
should
be heard as soon as the knob
is turned
to "light"
position.
If it is not present,
turn
burner
"off"
and make
sure that
power
is being
supplied
to unit.
Check
to see that
service
cord
is firmly
in
place
in receptacle
or for a blown
fuse or tripped
circuit
breaker.
If these
are not at fault,
remove
knobs
and handles,
four
(4) screws
from
control
panel
to check
connec-
tions
at valve
switches.
Remove
left
rear drip
pan, burner,
and remove
module
cover
to check
connections
at spark
module.
Make sure that solid
gt-ound
connection
is made from
spark
module,
The
broiler-
burner
ignition
is checked
in the same manner
as the top burner,
Since
it must be done with
the
griddle
level with
the cooktop,
ignition
is observed
through
the right
hand opening
between
the griddle
and
the
cooktop.
If ignition
does not take
place,
remove
drip
pan in right
rear burner
and reduce
air shutter
opening.
After
all burners
have been
individually
checked,
reattach
top,
if it has been removed,
and put drip
pans in
place,
Recheck
top
burner
ignition
and make
initial
flame
adjustment
one burner
at a time.
If flames
lift
from
burner,
reduce
air shutter
opening;
if flames,
are yellow,
increase
operling,
until
3/8"
soft blue inner
cone is present.
Check
ignition
on each burner
at least four
(4) times.
If burner
fails
to light
and ignitor
is clicking,
turn
gas "off",
remove
drip
pan and recheck
flash tube
alignment.
A visual
check
should
be
made
to make
sure that
the ignitor
is producing
a spark.
If spark
is
not
present,
recheck
connections.
Should
failure
continue
after
these
checks,
reduce
air
shutter
opening.
Replace
drip
pan
and
check
ignition
again.
(Try
at least 4 times.)
Now
proceed
to check
ignition
on both
front
and back
burners
at
one time.
Sometimes
the air shutter
opening
must be adjusted
to get proper
ignition
when
the other
burner
is burning.
Repeat
check
four
(4) times
on each side as before.
LOW
FLAME
ADJUSTMENT
Top
Burners
Low
flame
adjustment
IS made by lighting
burner,
turning
knob
to "low"
and removing
knob,
Hold
base of
valve
stem
with
pliers
and
insert
narrow
(3/16")
standard
blade
screwdriver
in adjustment
screw
slot
(located
in center
of valve stem).
Turn
screw until
flame
is l/8"
long,
Replace
knob.
"Lo"
SETTING
VALVE
AIR SHUTI'J3R
ADJUSTMENT
SCREW
AIR SHIJTTER
SCREW
MANIFOLD
BURNER
VALVE
2
NEEDIE