Major tech MT730 Gebrauchsanweisung - Seite 13
Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Messgeräte Major tech MT730 herunter. Major tech MT730 16 Seiten. Ac trms clamp meter
Range
Function
99.99nF*
Capacitance
(Auto-ranging)
999.9nF
9.999µF
99.99µF
999.9µF
9.999mF
99.99mF
Input Protection: 300V DC or 300V AC RMS.
* < 99.99nF (no specification)
Range
Function
Frequency with Test
10Hz to 100kHz
Leads (AC Voltage)
Input Protection: 1000V AC RMS
Sensitivity: > 15V AC RMS
Frequency (AC Current)
Function
Range
Frequency
45Hz to 1kHz
(AC Current)
Sensitivity: > 20A
Function
Range
20.0% to 80.0%
Duty Cycle
Range
Function
-20.0 to 1000°C
Temperature
-4.0 to 1832°F
Sensor: Type K Thermocouple
Input Protection: 300V DC or 300V AC RMS.
Testing Condition
Function
Forward DCA is approx .1mA,
Diode
open circuit voltage MAX 3V
Continuity
Test current MAX 1.5mA
Input Protection: 300V DC or 300V AC RMS.
Resolution
Accuracy ±(% of reading+digits)
0.01nF
±(4.5% + 20 digits)
0.1nF
0.001µF
±(3.0% + 5 digits)
0.01µF
0.1µF
0.001mF
±(5% + 5 digits)
0.01mF
Accuracy ±(% of reading+digits)
±(1.0% + 5 digits)
Accuracy ±(% of reading+digits)
±(1.0% + 5 digits)
Resolution
Accuracy ±(% of reading+digits)
±(1.2% + 10 digits)
0.1
Resolution
Accuracy ±(% of reading+digits)
0.1/1°C
±(3% + 3°C)
±(3% + 5°F)
0.1/1°F
Reading
Forward voltage drop of Diode
Buzzer makes a long sound,
While resistance is less than (50Ω)
7
7
7
7
13