Major tech MT775 Gebrauchsanweisung - Seite 8

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Messgeräte Major tech MT775 herunter. Major tech MT775 16 Seiten. Ac/dc trms clamp meter
Auch für Major tech MT775: Gebrauchsanweisung (20 seiten)

Major tech MT775 Gebrauchsanweisung
Function
Resistance
Input Protection: 300V DC or 300V AC RMS.
Function
Capacitance
Input Protection: 300V DC or 300V AC RMS.
Function
Frequency
:
Sensitivity
=>5VRMS
Function
Duty Cycle
Sensitivity:
=>5VRMS
Input Protection: 300V DC or 300V AC RMS.
Function
Temp
(Type-K)
(Probe accuracy not included)
Input Protection: 300V DC or 300V AC RMS.
Note: Accuracy is given as ±(% of reading + counts of least significant digit) at 23°C ±5°C,
with relative humidity less than 80%RH. AC voltage and current shall be subject to sine
wave.
8
Range & Resolution
600.0Ω
6.000KΩ
60.00KΩ
600.0KΩ
6.000MΩ
60.00MΩ
Range & Resolution
60.00nF
600.0nF
6.000µF
60.00µF
600.0µF
6.000mF
60.00mF
100.0mF
Range & Resolution
9.999Hz to 99.99kHz
Range & Resolution
10.0% to 90.0%
Range & Resolution
-20.0 to 1000°C
-4.0 to 1832°F
Accuracy ±(% of reading+digits)
±(1.0% + 4 digits)
±(1.5% + 2 digits)
±(2.5% + 3 digits)
±(3.5% + 5 digits)
Accuracy ±(% of reading+digits)
±(4.0% + 20 digits)
±(3% + 5 digits)
±(5% + 5 digits)
±(5% + 8 digits)
±(5% + 15 digits)
Accuracy ±(% of reading+digits)
±(1.2% + 5 digits)
Accuracy ±(% of reading+digits)
±(1.2% + 2 digits)
Accuracy ±(% of reading+digits)
±(3% + 5°C)
±(3% + 9°F)