Major tech MT403 Gebrauchsanweisung - Seite 5

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Sicherheitssensoren Major tech MT403 herunter. Major tech MT403 8 Seiten. Non-contact ac voltage detector

Low Voltage Mode (12 to 1 000V AC):
Hold down the 12V button. The green LED will change to yellow to
indicate the tester is in the low voltage mode. While pressing the 12V
button, place the tip of the tester near an AC voltage. When AC voltage is
detected, the yellow LED will turn off, the red LED will flash and the
beeper will beep. The flash and beeping rate will increase as the tester
gets closer to the voltage source. If the tester detects high voltage, it will
automatically change over to the high voltage mode: The red LED will
change to a steady glow and the beeper will beep rapidly.
NOTE: The tester cannot determine the actual voltage. The voltage level
where the tester switches from the low to high voltage mode is
effected by insulation type and thickness, distance from the
voltage source, and other factors.
Low Battery Indication:
Replace the batteries if the green LED does not turn on. When the tester
is on and the batteries are low, the beeper will beep 3 times and the
green LED will turn off indicating the tester is not operational. Replace the
batteries to restore operation.
Auto Power Off:
To conserve battery life, the tester will automatically turn off after
approximately 5 minutes of inactivity. When powering down, the beeper
will beep twice and the green LED will turn off.
Flashlight:
Press the Flashlight button to turn the flashlight on or off. To conserve
battery life, the flashlight will automatically turn off after approximately 5
minutes. The beeper will beep twice as the flashlight turns off.
NOTE: If the battery voltage is too low to operate the flashlight, the
tester will indicate this condition by beeping three times and the
flashlight will turn off. The voltage detector has it's own low
battery threshold and may remain operational.