IKEA DATID HGA4K Anweisungen - Seite 3

Blättern Sie online oder laden Sie pdf Anweisungen für Kochfeld IKEA DATID HGA4K herunter. IKEA DATID HGA4K 4 Seiten. Lagan
Auch für IKEA DATID HGA4K: Benutzerhandbuch (16 seiten), Handbuch (24 seiten), Montageanleitung Handbuch (20 seiten), Handbuch (12 seiten)

IKEA DATID HGA4K Anweisungen
INSTALLATION
Technical information for the Installer
If there is no oven beneath the cooktop (any oven installed
must be manufactured by us and equipped with a cooling
system), insert a separator panel at a minimum distance
of 20 mm from the bottom of the cooktop.
Note: before installation, make sure that the local gas
delivery conditions (nature and pressure of gas) are
compatible with the settings of the cooktop, as
indicated on the Product Description Sheet and on the
rating plate.
The outer surfaces of the furniture or appliances adjacent
to the cooktop must be heat resistant (heat protection
"Y") according to standards.
Installation must comply with current local regulations.
In the room where the cooktop is installed, there must be
enough air to allow the gas to burn correctly
(see the separate Product Description Sheet).
The natural flow of air must take place through an adequate
opening, that must be:
- permanent, made on one of the outside walls of the room,
and communicating with the exterior in an area away from
sources of pollution;
- built so as to ensure that its openings, both on the inside and
on the outside, cannot be obstructed, intentionally or
accidentally;
- protected by a metal grid or mesh that does not reduce its
working section;
- situated near the floor level and positioned so as not to
interfere with the operation of the fume exhaust devices.
- The fume exhaust has to take place through an appropriate
hood or fan installed on the wall or on the window.
Assembly
Important: the power supply cable and plug must be
suitable for the power absorption of the cooktop, and
the cable must be long enough to permit its upward
extraction.
Electrical connection
The electrical connections must comply with local
regulations.
The data relevant to the voltage and power absorption are
indicated on the rating plate.
The earthing of this appliance is compulsory by law.
The manufacturer cannot be held responsible for any
injury to persons or animals or damage to property
arising from failure to comply with these
requirements.
When the cooktop is installed, provide a multi-pole
circuit breaker with a contact separation of at least
3 mm.
If necessary, the electrical power cable must be
replaced exclusively with a power cable having
identical characteristics to the original supplied by
the manufacturer (type H05V2V2-F - T90°C or type
H05RR-F). This operation must be performed by the
After Sales Service or a qualified electrician.
L
Earth
(Yellow/Green)
N
Connection to gas supply
The gas supply system must comply with local
regulations.
You can find specific local regulations for some countries, in
the separate National Safety Regulations Sheet supplied.
If no information concerning your Country is given, please ask
details to your Installer.
The connection of the cooktop to the gas pipe network or gas
cylinder must be made by means of a rigid copper or steel
pipe with fittings complying with local regulations, or by
means of a continuous-surface stainless steel hose complying
with local regulations. Interpose gasket (B) in the elbow
connection.
The maximum length of the hose is 2 m.
FOR BELGIUM ONLY: It is necessary to replace the elbow
connection (A) on the appliance, with the one supplied.
Important: if a stainless steel hose is used, it must be
installed so as not to touch any mobile part of the
furniture. It must pass through an area where there are
no obstructions and where it is possible to inspect it on
all its length.
After connection to the gas supply, check for leaks with
soapy water.
Attention: Should you experience difficulty in turning
the burners knobs, please contact the After Sales
Service for the replacement of the burner tap.
ADJUSTMENT TO DIFFERENT TYPES OF GAS
If a different type of gas to the type shown on the rating plate and
on the orange sticker affixed to the top of the cooktop is used,
the cooktop must be converted to work with the new gas type.
Remove the orange sticker and affix it to the instructions booklet,
which must be retained for the lifetime of the appliance.
The gas nozzles must be changed by After Sales Service or
1.
a qualified technician.
Nozzles not supplied with the appliance must be ordered
from After Sales Service.
Connect the cooktop to the gas shut-off valve by means
2.
of a pipe suitable for the type of gas used, in compliance
with current local regulations.
3.
Adjust the minimum setting of the taps.
Note: when liquid petroleum gas is used (G30/G31), the
minimum gas setting screws must be tightened as far as they will
go.
Replacing the injectors
(see table in the enclosed
Product Description Sheet)
Remove grids (A).
1.
Extract burners (B).
2.
Using a socket spanner of the appropriate size (C),
3.
unscrew the injector to be replaced.
Replace it with the injector suitable for the new type of
4.
gas.
Re-assemble the injector in (D).
5.
Before installing the cooktop, remember to affix the gas
calibration plate supplied with the injectors in such a way that
it covers the existing information relating to gas calibration
Adjusting minimum gas setting of taps
To ensure that the minimum setting is correctly adjusted,
1.
remove knob (E) and proceed as follows:
tighten (-) to reduce the height of the flame;
loosen (+) to increase the height of the flame;
The adjustment must be performed with the tap in minimum
gas setting position (small flame)
.
Upon completion of adjustment, reseal using sealing wax or
an equivalent material.
The primary air of the burners does not need to be
2.
adjusted.
After the adjustment of the minimum gas setting, light up the burners
and turn the knobs from max. position
to min. position
check the stability of the flame.
to