IKEA SKALAN 805.235.71 Handbuch - Seite 18
Blättern Sie online oder laden Sie pdf Handbuch für Kochfeld IKEA SKALAN 805.235.71 herunter. IKEA SKALAN 805.235.71 24 Seiten.
ENGLISH
Gas connection
Warning! Refer to Safety
chapters.
Caution! Information for
authorised installer only.
Connection to main pipe
Warning! This appliance is not
connected to a combustion
products evacuation device.
Before you proceed with the
installation, make sure that the
local distribution conditions,
nature of the gas and gas
pressure, and the adjustment of
the appliance are compatible.
The installation must be compliant with the
current local regulations. Complying with the
local regulations, the connection of the
cooktop to the gas pipe network or gas
cylinder must be made by means of a rigid
copper or steel pipe with fittings, or by
means of a continuous surface stainless
steel hose.
If there is a problem with the
pipe, do not repair it yourself.
Contact the local After Sales
Service Provider. Refer to the
Service chapter.
The connection must be installed correctly
and fixed into the hob connection pipe.
1
2
Otherwise, gas may leak from the
connection pipe.
Warning! When you finish the
installation, check the sealing and
pipe fixing. To check the
installation, use soapy water. Do
not use the flame.
Gas setting conversion
You can check the parameters of
adjustment setting for this
appliance on the rating plate.
Refer to the Technical data
chapter.
You can use this model with
natural gas. However, you can
convert it for use with other
gases, providing the correct
injectors.
For more information on injector
replacement, refer to the Technical data
chapter.
Warning! Conversion or
replacement can only be
performed by a authorised
technician.
To replace injectors:
1. Remove pan support.
2. Remove burner cap and crown.
18