FOR SERVICE TECHNICIAN'S USE ONLY
Failure/Error Codes
If all the lights on the User Interface are Off and there is no response from the cooktop, complete the following steps:
1.
Disconnect power.
12. Change both power control boards.
2.
Check the continuity between the black lug on the terminal block and
13. Replace all parts and panels before operating.
both L1 and L2 terminals on the EMI filter board.
14. Reconnect power.
3.
Replace all parts and panels before operating.
15. Reconfigure the cooktop following the directions in
4.
Reconnect power.
Configuration Mode."
5.
Check that it is working. If it is not, go to Step 6.
16. Check that it is working. If it is not, go to Step 17.
6.
Disconnect power.
17. Disconnect power.
7.
Check the continuity of the fuses on the EMI board. If one or more of
18. Change the User Interface and cable.
the fuses is blown, replace with a new fuse.
19. Replace all parts and panels before operating.
8.
Replace all parts and panels before operating.
20. Reconnect power.
9.
Reconnect power.
21. Reconfigure the cooktop following the directions in
10. Check that it is working. If it is not, go to Step 11.
Configuration Mode."
11. Disconnect power.
There are 3 types of failures associated with the cooktop. The description of these failures and the impact they will have on the rest of the cooktop are
listed in the following.
Failure - Type 1
Failure type 1 comes from the power control board. This failure will affect only one burner. The user may continue to use the other burners.
Failure - Type 2
Failure type 2 usually comes from the power control board (there could be some exceptions). These failures affect all burners associated with that power
control board; the user may continue to use the burners that belong to the other power control board.
Failure - Type 3
Failure type 3 comes from the User Interface. This failure disables the entire cooktop. When this type of failure occurs, all the burners are switched Off by
the User Interface.
Service Code
Shown on Display
F-12
Failure Description
Coil under current
Type of Failure
Type 1
Repair Suggestions
1.
Disconnect power.
2.
Check for the correct connections at T2A - T2B or T3A - T3B on
the power control board (whichever connection the burner is
plugged into). If connections are correct, go to Step 3.
3.
Replace the burner coil.
4.
Replace all parts and panels before operating.
5.
Reconnect power.
6.
Reconfigure the cooktop following the directions in "Manual
Configuration Mode."
7.
Check for proper operation.
8.
If everything operates, end service. If error code still appears,
disconnect power and go to Step 9.
9.
Replace the power control board.
10. Replace all parts and panels before operating.
11. Reconnect power.
12. Reconfigure the cooktop following the directions in "Manual
Configuration Mode."
F-21
Supply power frequency
Type 2
1.
Disconnect power.
2.
Replace the power control board.
3.
Replace all parts and panels before operating.
4.
Reconnect power.
5.
Reconfigure the cooktop following the directions in "Manual
Configuration Mode."
6.
If the issue is not fixed, contact a qualified electrician to verify the
frequency of the home power supply is 60 Hz.
F-25
Stuck fan on power control board
(right or left side fan, depending on
which side of the display the
failure is on)
Type 2
1.
Disconnect power.
2.
Check that the cooling fan connector is firmly plugged in.
3.
Replace all parts and panels before operating.
4.
Reconnect power.
5.
If the issue is not fixed, disconnect power.
6.
Replace the cooling fan.
7.
Replace all parts and panels before operating.
8.
Reconnect the power.
9.
If the issue is not fixed, disconnect power.
10. Replace the power control board.
11. Replace all parts and panels before operating.
12. Reconnect power.
13. Reconfigure the cooktop following the directions in "Manual
Configuration Mode."
2