Troubleshooting

Problem
Compressor not
running .
Condensing units
run for long periods
of time .
Cabinet temperature
is too warm .
Cabinet temperature
is fluctuating .
Condensation is
collecting on the
cabinet and/or floor .
Interior light is not
working .
www.AvantcoRefrigeration.com
10
Possible Cause
Fuse blown or circuit breaker
tripped .
Power cord unplugged .
Thermostat set too high .
Cabinet in defrost cycle .
Excessive amount of warm
product placed in cabinet .
Prolonged door opening or door
ajar .
Dirty condensor coil .
Evaporator coil iced over .
Thermostat set too warm .
Airflow blocked .
Excessive amount of warm
product placed in cabinet .
Fuse blown or circuit breaker
tripped .
Dirty condenser coil .
Evaporator coil iced over .
Low refrigerant levels .
Door is slightly ajar .
Relative humidity is above 55% .
Poor switch connection .
Bulb is not connected .
Bulb is burned out .
User Manual
Refrigerated Bakery Display Cases
Possible Solution
Replace fuse or reset circuit breaker .
Plug in power cord .
Set thermostat to lower temperature .
Wait for defrost cycle to finish .
Allow adequate time for product to cool down .
Ensure doors are closed when not in use . Avoid opening doors
for long periods of time .
Clean the condenser coil . (Page 9)
Unplug unit and allow coil to defrost . Make sure thermostat is not
set too cold . Ensure that door gasket(s) are sealing properly .
Set thermostat to lower temperature .
Re-arrange product to allow for proper air flow . Make sure there
is at least four inches of clearance from evaporator .
Allow adequate time for product to cool down .
Replace fuse or reset circuit breaker .
Clean the condenser coil . (Page 9)
Ensure doors are closed when not in use . Avoid opening doors
for long periods of time .
Contact a service technician to check refrigerant levels .
Make sure door is completely closed .
Move unit to area below relative humidity or lower humidity level .
Turn off light switch and turn it back on .
Make sure the bulb is correctly inserted in the socket .
Replace the bulb .