J1 position 2-3 : NC relay contact (factory configuration).
Checking TX - RX (LED 1) alignment:
Led 1 is installed on the receiver indicating when the TX - RX
pair of photocells is aligned.
Led 1 will be on steadily when the infrared ray is aligned and will
go off the when infrared ray goes off.
Checking the quality of the received signal ( LED 2 ) :
Led 2 is installed on the receiver and flashes based on the qual-
ity of the signal received from its matching transmitter. The
number of flashes is proportional to the intensity of the signal
being received; four flashes, maximum signal, one flash is a
weak signal.
------------------------------------------------------------------------------
IMPORTANT FOR THE INSTALLER
- If installing multiple devices it is advisable to cross beams (i.e.
transmitter A and receiver B on the left and transmitter B and
receiver A on the right). If this were not possible maintain a dis-
tance (especially between receivers) of at least one metre.
I
'
MPORTANT FOR THE USER
S
- The device must never be used by children or persons with
reduced physical-psychological abilities, unless supervised or
trained on the functioning and the use modalities.
- Do not allow children to play with the device and keep the
radio-controls away from their reach.
- ATTENTION: keep this instruction manual and respect the
important safety prescriptions contained herein. The non com-
pliance with the prescriptions may cause damages and serious
accidents.
- Frequently examine the plant to detect any signs of damaging.
Do not use the device if a repair intervention is necessary.
Attention
All operations which require the opening of the casing (cables
connection, programming, etc.) must be carried out by expert
personnel during installation. For any further operation which
requires the casing to be re-opened (re-programming, repair or
installation amendments) contact the after-sales assistance.