• Select a location away from heat and moisture-generating equipment.
a. Ambient temperatures above 75 degrees Fahrenheit may cause the compressor to
malfunction.
b. The unit should not be used in areas over 90 degrees Fahrenheit.
c. Malfunction due to ambient temperatures above 75 degrees Fahrenheit will void warranty.
d. Do not install the unit inside a closet or alcove.
• For optimal performance, 3" of clearance is required around all louvered or vented panels to allow
for proper air flow.
a. For your convenience, a set of brackets is included to prevent this unit from being pushed
up against a wall.
b. Component failure due to improper installation is not covered under warranty.
Electrical
• Please ensure that the required voltage is being supplied at all times.
• The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate
over-current protection. Please refer to the electrical requirements on the unit's nameplate.
• The unit should have its own dedicated outlet.
• Do not use extension cords.
• Ensure the unit is not resting on or against the electrical cord.
• If the unit is not in use for a long period of time, please unplug the unit from the outlet.
• To avoid shock and fire hazards, do not plug in or unplug the unit with wet hands.
• After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could
cause damage to the compressor.
Temperature Controls
• Refrigerant LED - Compressor is on
• Fan LED - Fan is on
• Defrost LED - Defrost cycle is running
Functions
ADJUSTING THE TEMPERATURE
Your new refrigerator or freezer is already factory-set to run at optimum temperatures for food safety
and should require no adjustments.
Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a
maximum temperature of 40 degrees Fahrenheit.
Freezers are set to cycle between a minimum temperature of -5 degrees Fahrenheit and a maximum
temperature of 2 degrees Fahrenheit.
www.AvantcoRefrigeration.com
User Manual