Avantco 189WVAC36HC Benutzerhandbuch - Seite 6

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Merchandiser Avantco 189WVAC36HC herunter. Avantco 189WVAC36HC 10 Seiten. Vertical open air merchandisers
Auch für Avantco 189WVAC36HC: Benutzerhandbuch (7 seiten)

Avantco 189WVAC36HC Benutzerhandbuch
Running a Manual Defrost Cycle
This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you would like to
run a manual defrost cycle at any time, please follow the steps below:
1. Press the defrost button (snowflake symbol and down arrow) for approximately 3 seconds.
2. Repeat to stop the defrost cycle.
Defrost System:
Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor downtime,
the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil
temperature above the freezing point, melting any accumulated frost. Run-off water is drained into the
evaporator pan and evaporated. Automatic defrost timers automatically initiate at pre-set intervals and for a
pre-determined duration.
If drainage pipe is available, lower the condensation drainage pipe and connect to a drain or condensa-
tion pump. Verify the pipe is unobstructed and it is lower than the water reciever indicated by the line on
the sticker.
If no drain is available, the condensation drainage pipe can be hung up. The excess water will be evapo-
rated with the condensate evaporator pan. Note that the use of this option will increase the energy
consumption of the unit.
WARNING: High humidity enviroments can cause increased amounts of condensation that can over-
flow the evaporator pan. Connecting the drainage pipe to a nearby drain is necessary for enviroments
exceeding 55% relative humidity.

Safety / Warning

Please pay close attention to the safety notices in this section. Disregarding these notices may lead to seri-
ous injury and/or damage to the unit.
ATTENTION
To minimize shock and fire hazards, be sure not to overload outlet. Please designate one outlet for
your unit.
Do not use extension cords.
Do not put your hands under the unit while it is being moved.
When the unit is not in use for a long period of time, please unplug the unit from the outlet.
After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could
cause damage to the compressor.
UNPLUG CORD
To minimize shock and fire hazards, please do not plug or unplug the cord with wet hands.
During maintenance and cleaning, please unplug the unit.
www.AvantcoRefrigeration.com
6
User Manual
Vertical Open Air Merchandisers