It is important to clean the merchandiser twice a year. In order to avoid mould formation, odours, etc.
product compartments must also be thoroughly cleaned. The interior of the ICM should be cleaned
with a mildly soapy cloth and the glass surface using a window-cleaning agent.
5. Troubleshooting
If the ICM is not functioning properly or is out of order, please check the following before calling the
authorized service provider:
In case the merchandiser is placed in very dusty and/or greasy
environment, the regular cleaning of the condenser by an
authorized technician is mandatory.
Keep the cooler in a stable position during cleaning, do not step on
or lean over the cooler.
Do not clean with sharp objects, flammable or corrosive liquids or
sprays.
ALL ACCESS TO THE COOLING SYSTEM AND ELECTRICAL PARTS
(CHANGING LIGHTING OR REFRIGERATION DECK) MUST BE
PERFORMED BY AUTHORIZED SERVICE PERSONNEL ONLY.
Flex 20 HC, Flex 20 C HC, Flex 100 HC, Flex 100 C HC, Flex 130
HC, Flex 130 C HC, Flex 130 C SZ HC, Premium Slim 130
[R600a] and Bar-45 [R600a] are equipped with HC refrigerant.
All service operations on cooling mechanism & gas charging
should be performed in a well ventilated environment or in
open air. Do not smoke during maintenance.
UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR
SERVICE OPERATIONS. REMOVE THE PLUG AND MAKE SURE
THAT THE OPERATOR CAN CHECK FROM ANY OF THE POINTS
WHICH HE HAS ACCESS THAT THE CABLE IS UNPLUGGED.
After maintenance operations, make sure that the grounding
connections are in place before assembling the covers. Make sure
you use the same fastening components and covers.
If any electrical components need to be replaced, use only the
identical components in the spare part list supplied by the
technical service department of Frigoglass.
Keep the glass door of the cooler closed during cooling
mechanism maintenance. The appliance will not stand stable when
the compressor is disassembled. If the compressor needs to be
replaced, use adequate support to stabilize the cooler.
After maintenance operations make sure that the strain relief,
which supports the supply cord, is assembled properly.