8.
Upgrade Line Count
To add additional lines, remove the plastic divider and install
modules in next available position as required. Replace remaining
plastic divider segments in any unused positions.
With the module at 45 degrees and mounting feet aligned with
openings in base (Figure 8), press feet into openings and rotate
telco terminal end of the module onto the ground bar tang until
ground clip is fully engaged.
9.
Testing
9.1
Continuity of the Telco Wiring
Step 1:
With the stuffer in the down position, insert test clips into the center of the
test holes on top of the protector in the orientation shown (Figure 9).
Step 2:
Test per standard company practices.
9.2
Continuity of the Subscriber Wiring
Step 1:
Open the line module door by sliding the orange latch to the right. Insert
test clips into the test ports on the subscriber line module in the orientation
shown for each test to check continuity of the entire line module or to
check each line (Figure 10). Move the orange levers to the connected and
disconnected positions to check each individual line.
Step 2:
Test per standard company practices.
Step 3:
Slide the orange module latch all the way to the left and close the module
door.
Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA
800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/opcomm
Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products
without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other
trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2009, 2015 Corning Optical Communications.
All rights reserved.
STANDARD RECOMMENDED PROCEDURE 203-297 | ISSUE 2 | MAy 2015 | PAGE 4 OF 4
Test Telco/Network continuity
from line module to protector with
test clips in this position.
Ground
Bar
Test Subscriber/Customer continuity to
each subscriber line inside the premises
with test clips in this position.
Toggle the orange lever for each
separate line.
KPA-2328
Press Down
KPA-2324
Insert foot of adapter
into opening in NID.
Figure 8k
KPA-2329
Figure 9
Figure 10