GarageAce S6 Benutzerhandbuch - Seite 17
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Garagentoröffner GarageAce S6 herunter. GarageAce S6 20 Seiten. Sectional/tilt garage door opener
Troubleshooting Guide
Fault
Opener not working at all
LED displays "-" – opener doesn't
work
The door opens but does not close
Open and close action works in
reverse
Door auto reverses to full open
before competely closing
Remote doesn't work
Can't add new remotes
LED displays "C" – opener doesn't
work
LED displays "H" – opener doesn't
work
LED displays "H" after opener
moves door only centimeters
Loud banging noise when door
tries to operate
Cause
1. Power supply disconnected
2. Loose wiring
1. Faulty setting of the travel limit
1. Photo beam obstruction
2. Photo beam setting is turned on
but no photo beam is installed
1. The positive and negative motor
wires on the control board are
reversed
1. There was an obstruction
2. Travel limits may not be set
correctly
3. Some older doors have
unbalanced springs
1. Flat battery in the remote
2. Motor antenna is loose or not
extended
3. Nearby interference
1. Memory is full
2. New remote is from another
brand
1. Motor cord is loose
2. Control board is damaged
1. Motor is damaged
1. Magnetic position sensor has
loose wiring to the control board
2. Magnetic position sensor or
control board is damaged
1. Belt drive is too loose
Solution
1. Check the power supply
2. Carefully open the motor cover
and check all wiring is connected
and there are no loose plugs
1. Reset the travel limits (page 11)
1. Remove obstruction
2. Cancel then photo beam setting
(see page 13)
1. Unplug the power to the motor,
remove the motor cover and
reverse the positive and negative
wires
1. Remove obstruction
2. Reset the travel limits (page 11)
3. Increase the operating force
(page 12)
1. Replace the remote battery
2. Check the antenna and fully
extend
3. Get rid of interference
1. Check that the memory is full and
clear if required (see page 11)
2. Use GarageAce™ remotes only
1. Reinsert motor cord
2. Replace control board (refer
supplier)
1. Replace motor (refer supplier)
1. Turn the power off, remove the
motor cover and check the sensor
wiring
2. Replace the magnetic sensor or
control board (refer supplier)
1. Tighten belt drive
S6 Instruction Manual
TM
17