Install Jumpers

Step 1:
Remove dust caps from the connectors and adapters into which they will be mated.
Refer to Section 5 for cleaning instructions or clean connector end-faces and
adapters per standard company practices and insert connectors into adapters.
Step 2:
Install jumpers as specified on planning diagrams. The panel can be raised to access
the adapters on the bottom row. When raising the panel, the cover must be removed
to prevent damage to the connectors on the back side of the panel. Cut the provided
hook-and-loop strap into small sections and feed the strap through the appropriate
lance at the front of the housing. Loosely secure jumpers using the straps at the front
of the housing (Figure 10).
KPA-1023
Step 3:
Provide enough jumper slack to allow the connector panel tray to slide backward and
forward without violating the minimum bend radius of the jumper.
Step 4:
Record jumper routing information on the provided identification label. The
identification panel can be removed, if desired. Accurate recordkeeping is imperative
for an organized installation.
5.

Connector Care and Cleaning

WARNING: Isopropyl alcohol is flammable with a flashpoint at 54ºF. It can cause irritation to
eyes on contact. In case of contact, flush eyes with water for at least 15 minutes. Inhalation
of vapors irritates the respiratory tract. Exposure to high concentrations has a narcotic effect,
producing symptoms of dizziness, drowsiness, headache, staggering, unconsciousness and
possibly death.
Always keep dust caps on connectors and adapters when not in use.
Ensure dust caps are clean before reuse.
Use optical cleaning materials as standardized by your company.
Clean the connector before every mating, especially for test equipment patch cords
(jumpers).
A minimum level of cleaning is listed below. Local procedures may require more rigorous
cleaning methods.
Step 1:
Remove plugs from the connector adapter.
Step 2:
Wipe the connector ferrule twice with a lint-free wiping material moistened with
isopropyl alcohol. Then wipe across the end of the ferrule.
Step 3:
Repeat previous step with a dry wipe.
STANDARD RECOMMENDED PROCEDURE 003-723 | ISSUE 2 | OCTObER 2015 | PAGE 8 OF 9