12.
OPTIC FIBER CONNECTION
Notes:
• The fiber connections are performed from the GX
towards the OCH (at the headend) via the fiber optic
patch panel.
• In MIMO configurations with two GX units, the pair
of optical fibers connected between the OCH optical
modules and GX remote units must be equal in
length to ensure the same time delay to both units.
• Keep in mind the rules for handling and connecting
fiber optic cables. The fiber optic cables will
be connected to the associated OCH in the
communication room at a later phase.
• GX supports single-mode fiber.
• An OptiTap® cable (ordered separately) is used for
the fiber optic connections.
• It is recommended to allow a drip loop when
connecting.
Step 1:
Install splice box near the remote unit.
Step 2:
Referring to Figure 14, connect OptiTap cable to
splice box and to the GX OP OptiTap port.
13.
POWER UP UNIT
ATTENTION! Any open RF port on GX or improper connection
between GX RF ports and combiner input ports will damage
GX internal power amplifier after the equipment is powered
on. Make sure all connections are performed correctly before
powering.
13A. POWERING UP AC MODELS
Step 1:
Unscrew the two screws of the side panel and open
to access the power connector. See Figure 15.
Step 2:
Connect the supplied power cable to the power
supply port: (VAC 100-240/47-63 Hz, 20A max).
Maximum power consumption: 1450 W
Corning Optical Communications
Figure 14. GX Fiber Connection
Figure 15. GX AC Model Power Connector
Quick Installation Sheet | CMA-581-AEN | Page 12