CORNING EDGE EDGE-BKT-LR-2RU Handbuch - Seite 2

Blättern Sie online oder laden Sie pdf Handbuch für Racks & Ständer CORNING EDGE EDGE-BKT-LR-2RU herunter. CORNING EDGE EDGE-BKT-LR-2RU 6 Seiten. Rackless mounting kits

2.4
Ladder Rack Mounting Kit 4U (EDGE-BKT-LR-4RU)
• (1) Bottom plate / (2) omega brackets and (2) support
bars preinstalled
3.

Tools and Materials Required

• Phillips screwdriver
4.

Kit Preparation

Before installing the kit into the wire tray or ladder rack, determine the number and size of the housings to be
installed into the kit. Housing installation begins at the top of the kit.
2U Mounting Kit accepts:
(1) EDGE-02U
(2) EDGE-01U
Step 1:
If less than the full capacity of housings will be installed into the kit, move the support bars from
their factory-installed positions so that they are positioned just below the lowest housing that will be
supported.
Step 2:
Install the kit into the wire tray or ladder rack as described in Section 5 or 6.
Step 3:
Then mount the housings, beginning at the top of the kit. Ensure that the lowest housing rests on the
support bars.
TPA-5841
TPA-5832
4U Mounting Kit accepts:
(1) EDGE-04U
(2) EDGE-02U
(4) EDGE-01U
(2) EDGE-01U and (1) EDGE-2U
Standard Recommended Procedure 003-809 | Issue 7 | May 2017 | Page 2 of 6
Figure 1