BEROTEC Mofessor Handbuch - Seite 14
Blättern Sie online oder laden Sie pdf Handbuch für Schmierungssysteme BEROTEC Mofessor herunter. BEROTEC Mofessor 16 Seiten. Automatic chain lubrication system
Auch für BEROTEC Mofessor: Handbuch (16 seiten), Benutzerhandbuch (12 seiten)
6.
Troubleshooting
problem
no oil on the chain
soiled rear wheel
oil is leaking even
though ignition is turned
off
red LED isn't working or
turning off by itself
red LED is flickering
red LED is permanently
on
dosing valve doesn't
work
7.
Disposal
Nonfunctional systems shouldn't be disposed as a whole but as individual parts
depending on the material. Non-recyclable parts have to be disposed according
to their type.
BEROTEC GmbH
Manual
possible reason
- tank empty
- nozzle blocked
- kinked hose
- nozzle misadjusted
- electric connections not
properly connected
- rain-mode not deactivated
after rain
- oil flow misadjusted
- control voltage cable is
connected to permanent
+12V
- hose damaged
- electric connections not
properly connected
- control voltage cable not
properly connected
- rain-mode switch cable is
located too close to parts of
the ignition system
- control voltage too low
- fuse broken
- connection failure
MOFESSOR
action
→ refill oil
→ clean nozzle
→ check hose
→ check nozzle position
→ check connections
→ put rain-mode switch in
field of view
→ reduce oil flow
→ see chapter 4.5
→ check hose
→ check connections
→ see chapter 4.5
→ re-lay cable
→ check 12 V on control
voltage cable (black/white)
→ check fuse / fuse holder
→ check valve connection
P a g e
| 13