Gardasoft Vision PP860 Benutzerhandbuch - Seite 15
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Controller Gardasoft Vision PP860 herunter. Gardasoft Vision PP860 17 Seiten. Led lighting controller
A. Error Codes
Error codes may be displayed by the PP860. These are shown as "E nn", where
nn gives the number of the error. The error codes are:
Et
The PP860 has a thermal cutout. If the internal temperature reaches 62
which corresponds to a case temperature of approximately 60
output currents are turned off. This message will persist until the PP860
o
has cooled down below 60
E1
One of the parameters to a command has an illegal value.
E2
On power up, the stored configuration was invalid.
E4
The RS232 command has the wrong number of parameters.
E16, 17, 18
Invalid command.
E 40
When the unit has powered up the non-volatile memory was corrupt and
has been cleared. Set up the unit again.
All other errors
A hardware error has occurred. Try power cycling the unit and trying
again to see if the fault clears. If not, make a note of the number and
contact your distributor.
15
c.
o
c,
o
c, the