Avastor XD5 Benutzerhandbuch - Seite 7

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Gehege Avastor XD5 herunter. Avastor XD5 19 Seiten. Desktop raid

RAID MODE CONFIGURATION & REBUILD
The XD5 standard configuration is configured for RAID 5 using five drives. This
mode improves speed and combines the drives into one large drive with
redundancy if any one of the drives were to fail.
Please review the RAID mode options under "RAID Configurations" in this
manual to choose the most suitable RAID mode for your application.
SETTING AND CHANGING THE RAID MODE
NOTE: All RAID mode settings and changes are made from the Clear RAID
mode. Ensure the RAID mode is set to Clear RAID or if you are changing the
RAID mode, ensure the RAID mode has been changed to Clear RAID mode.
Setting the Clear RAID Mode
Move the 3 RAID selector switches to the Clear RAID mode position
(down/down/down). Power the XD5 to off. While pressing the SET button,
power the XD5 to on, continue to press the SET button. The XD5 will beep
once, confirming power is on and RAID mode change is in progress. After 5-10
seconds the XD5 will beep once again, confirming the RAID mode has been
changed, release the SET button. The XD5 is now in Clear RAID mode.
Setting the RAID Mode or Changing the RAID Mode
Ensure the RAID mode is set to Clear RAID or if you are changing the RAID
mode, ensure the RAID mode has been changed to Clear RAID mode.
From the Clear RAID mode, set the 3 RAID Mode selector switches to the
desired RAID mode. See the chart below for the RAID Mode Selector Switch
position setting.
7
VER 1.0