MAIN BURNER FLAME CHARACTERISTICS

Main Burner Flame Pattern
The main burner flame will be completely yellow.
Keep the control compartment and burner area surrounding the
burner clean.
Always keep the appliance area clear and free from combustible
materials, gasoline, and other flammable vapors and liquids.
Never obstruct the flow of combustion and ventilation air. Keep the
front of the appliance clear of all obstacles and materials.
Cleaning Instructions
This appliance is built using mostly high-grade stainless steel to
resist rust-through. In outdoor applications, all stainless steel will
develop a dull patina and, depending on the local environment
and on the materials used in the installation, may develop some
surface oxidation (rust). This does not affect the performance of
GAS CONTROL
VALVE
HI/LO
PILOT
Solenoid
MAIN
PILOT
ORANGE
(IGNITOR)
RED
BLACK
37139-8-1219

CLEANING AND SERVICING

CUSTOMER PROVIDED
WALL SWITCH
BROWN
WHITE
GREEN
ORANGE
(GND)
ELECTRONIC
BLACK
CONTROL MODULE
(SENSOR)
AF-4000 B/P
BLACK
ORANGE
Main Burner Flame Ignition and Extinction
When the main burner is ignited it will take a few seconds for the
full flame pattern to develop.
When the main burner is extinguished it will take a few seconds for
the flames to disappear.
the fireplace, and does not require any action to correct. If you
prefer keeping your fireplace front looking factory-fresh, clean it as
required with stainless steel cleaner.
When installation application includes highly acidic applications
such as mortar or stone etching, do not remove the protective PVC
film from the stainless steel until after this application is complete.
Once the film has been removed we recommend that the appli-
ance be cleaned with a stainless steel cleaner immediately.
Please note that areas where the film has been formed (corners,
hems, etc.) may require extra cleaning due to the properties of
the film. Ensure that all protective film has been removed from the
fireplace prior to burning the appliance.

WIRING

N/A
BROWN
RED
NOTICE: The fireplace may be operated without the remote by
connecting the brown control module wires to a wall switch. The
remote/off switch on the control module must be in the "OFF"
position.