Gardena 1753 Betriebsanleitung - Seite 8

Blättern Sie online oder laden Sie pdf Betriebsanleitung für Water Pump Gardena 1753 herunter. Gardena 1753 17 Seiten. Pressure tank unit

Gardena 1753 Betriebsanleitung
Cleaning the check valve:
t
1
2
o
p
7. Trouble­Shooting
Problem
The pump sucks nothing up.
18
1. Turn the rotary switch
2. If necessary, close all valves on
the intake side.
3. Open all pressure side outlets,
so that the pressure side is
depressurised.
4. Unscrew the end cap
drain off the water (see 5. Storage
"To put into storage").
o
5. Undo screw
i
into the bearing groove.
6. Screw out the cover
a suitable tool).
t
7. Remove the valve body
8. Refit in reverse order.
9. Switch the Pressure Tank Unit back on again
(see 4. Operation).
DANGER! Electric shock!
v Unplug the cable at the mains before
trouble­shooting.
Work on the electrical parts must only be carried out
by GARDENA Service Centres.
Possible Cause
Rotary switch is not turned to
RUN.
The pump is sucking air
through a leak at a connection
on the suction side.
Pump is not adequately primed
with the liquid to be pumped.
Air cannot escape on the pres-
sure side, because the pressure
side outlets are closed.
End of the suction hose is not
in the water, the non-return valve
at the end of the suction hose
is missing or leaking, the suction
hose is kinked, connections are
leaking or the suction filter is
blocked.
q
to FILL.
9
and
p
and slide the clip
upwards 1 and to the rear 2
t
of the check valve (if applicable using
i
and wash it under running water.
Remedy
v Restart the pump
(see 4. Operation).
v Check all connections and
make them air-tight as
necessary.
v Fill the pump and ensure that
the water is able to flow
back into the pressure line
(see 4. Operation).
v Open the pressure side
outlets.
v Check the complete suction
hose from suction point
through to the pump for leak-
tightness and repair any leaks
as necessary. Check the intake
side water supply. If applicable,
clean the suction filter.
FILL
q
RUN