B. Strain relief required
Clamping
Insert from
screws
"--J
under frame
4. Replace terminal block cover.
Disconnect
clamping
ring from strain relief. Push
relief (from bottom) through hole beneath terminal
block. Tighten clamping ring (from above) onto
strain relief threads.
Run cord through
strain relief
Run (cord or cable through strain relief.
Leave enough slack to attach ring-type terminals to
terminal block. Tighten clamping screws.
C. If ii-ame grounding
is allowed
Lir!el
AV
Line 2
Y--l*
/e
i
y+
relic,
Stram
Use this wiring method ONLY if local codes permit
connecting frame grounding conductor to neutral
wire of power cord.
THIS APPLIANCE IS MANUFACTURED WITH NEU-
TRAL TERMINAL CONNECTED TO THE FRAME.
1.
Connect neutral wire to the center silver-colored
terminal.
2. Connect remaining
2 wires to the terminals on
either side of the silver-colored
terminals.
3. Use ring type terminals
only. Connect with the
brass nuts that are taped to the frame. Do not
loosen factory installed nuts already on the
terminal.
D. 4-w&e electrical
connections
If local codes do not permit grounding
through the
neutral,
the 3-conductor
cord or cable assembly
must be replaced by a 4-conductor
cord. The
replacement
cord must be rated at 240 volts, 50
amperes and investigated
for use with ranges.
Silver-colored
_
terminal
Line 1 If-
/s%
f-----W
Line 2
Use this wiring method for mobile homes and
whenever a 4-wire installation is required.
1.
Remove the grounding
strap screw from the
range frame. Keep this grounding
screw. Bend up
the grounding
strap so that it does not contact the
range frame.
2. Connect the green grounding
wire to the frame of
the appliance
with the grounding
screw, using the
hole in the frame where the grounding
strap was
removed.
3. Connect the white neutral wire of the power
cord to the silver-colored
terminal of the terminal
block. Connect the remaining wires to the outer
terminals.
4. Replace the terminal block cover.
Neutral