Gardena 9048 Benutzerhandbuch - Seite 6

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Water Pump Gardena 9048 herunter. Gardena 9048 11 Seiten. Clear/dirty water submersible pump

Gardena 9048 Benutzerhandbuch
Automatic mode with float switch [ Fig. O2 ]:
By adjusting the float switch
(5)
mine the switching heights. For safe operation, the float switch
must be able to move freely around the pump.
To adjust the Cut-in and Cut-out Height [ Fig. O2 ]:
The maximum cut-in height and minimum cut-out height
(see 7. TECHNICAL DATA) can be adjusted by pushing the float
switch wire into the float switch lock.
• The higher the cable is clamped, the higher the cut-in and cut-out
height.
• The shorter the length of cable between the float switch
switch lock
(A)
, the lower the cut-in height and the higher the cut-out
height.
Cut-in and cut-out heights in mm:
Without clamp
Upper clamp
Off
On
Off
Clear water
90
500
150
Dirty water
120
550
200
1. Push the cable of the float switch
float switch lock
(A)
.
2. Check that the pump switches off automatically.
CAUTION!
In order to ensure that the float switch is able to switch on
and off, the cable length between the float switch and the
float switch lock must be at least 10 cm.
Manual operation [ Fig. O3 ]:
The pump remains permanently in operation because the float
switch is bypassed.
1. Slide the float switch
(5)
with the cable downwards onto the float switch
(A)
locking device
.
2. Place the pump on a firm surface.
3. Connect the pump to the mains.
Attention! The pump begins operating immediately.
The pump runs permanently without dry-running protection due to the
bypassed float switch. To avoid damage due to dry running, only operate
under supervision.
The minimum residual water depth (see 7. TECHNICAL DATA) is only
achieved with the pedestal retracted in manual mode because the float
switch already switches off the pump before this when in automatic mode.
To change the function mode:
The pump can be switched between clear water and dirty water.
To do this, the pedestal is extended or retracted.
To extend the pedestal (dirty water) [ Fig. O4 – O7 ]:
1. Take the pump out of the water [ Fig. O4 ].
2. Lift up the pump and push the button
extended [ Fig. O5 ].
3. If the pedestal does not extend completely, stand with your feet on
the wings of the stand and pull the pump upwards [ Fig. O6 ].
4. Release the button
(6)
again before you put the pump back down
[ Fig. O7 ].
The max. delivery rate is achieved with the pedestal extended.
The pedestal is correctly locked in position when the button is fully
extended. If the button is not fully extended, repeat the process.
To retract the pedestal (clear water) [ Fig. O8 – O11 ]:
1. Take the pump out of the water [ Fig. O8 ].
2. Place the pump on a firm surface and push the button
3. Push the pump down until the pedestal
the handle [ Fig. O10 ].
4. To lock, push the pump down until the button
again [ Fig. O11 ].
5. When submerging the pump again, make sure that it is on a firm
surface so that it cannot get stuck (e. g. foil).
The minimum residual water depth (see 7. TECHNICAL DATA) is only
achieved with the pedestal retracted in manual mode.
For best possible suction, we recommend switching to clear water mode
when the water level has reached the turquoise ring.
10
you have the pos sibility to deter-
(5)
and the float
Middle clamp
Lower clamp
On
Off
On
Off
340
130
320
110
380
180
360
160
(16)
into one of the openings of the
(6)
until the pedestal
(7)
is fully
(6)
[ Fig. O9 ].
(7)
is fully retracted and release
(6)
is fully extended

4. MAINTENANCE

DANGER! Risk of physical injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before you maintain
the product.
To clean the pump:
DANGER! Risk of physical injury!
Risk of injury and risk of damage to the product.
v Do not clean the product with a water jet (in particular
high-pressure water jet).
v Do not clean with chemicals including petrol or solvents.
Some can destroy critical plastic parts.
v Clean the surface of the pump with a damp cloth.
On
300
To flush the pump:
340
After pumping water containing chlorine, detergents or heavily soiled
water, the pump must be flushed.
1. Pump lukewarm water (max. 35 °C), possibly adding a mild cleaning
agent (e. g. detergent) until the pumped water runs clear.
2. Flush the button if the water is very dirty.
3. Remove residuals according to the waste disposal laws applicable in
your area.
To clean the button [ Fig. M1 ]:
If the button gets stuck due to dirt, it can be cleaned.
1. Push in the two lockings
2. Pull off the button
(6)
(6)
3. Clean the button
water.
4. Reassemble the button
5. STORAGE
To put into storage:
The pump is not frost-proof!
The product must be stored away from children.
1. Disconnect the pump from the mains.
2. Turn the pump upside down until no more water runs out.
3. Clean the pump (see 4. MAINTENANCE).
4. Store the pump in a dry, enclosed and frost-free place.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household
waste. It must be disposed of in line with local environmental
regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling
collection centre.

6. TROUBLESHOOTING

DANGER! Risk of physical injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before you
troubleshoot the product.
To clean the pedestal and the impeller [ Fig. T1 / T2 ]:
If the pedestal cannot be changed according to the chapter
3. OPERATION To change the function mode, the pedestal must
be cleaned.
1. Unscrew the 4 Phillips screws
2. Pull the suction base
3. Unscrew the 4 Phillips screws
4. Pull the pedestal
(7)
(13)
.
.
(13)
, the lockings
and the handle under running
(6)
in reverse order.
(8)
.
(9)
off the pump.
(10)
.
off the suction base
(9)
.