KitchenAid KHTU705S Handbuch der Abmessungen

Blättern Sie online oder laden Sie pdf Handbuch der Abmessungen für Lüftungshaube KitchenAid KHTU705S herunter. KitchenAid KHTU705S 1 Seiten. 30” and 36” range hoods
Auch für KitchenAid KHTU705S: Handbuch der Abmessungen (1 seiten)

KitchenAid KHTU705S Handbuch der Abmessungen
PRODUCT MODEL NUMBERS
KHTU705R
KHTU705S
KHTU765S
KHTU765R
Electrical: 120-V, 60-Hz, AC-only, 15 amp.
electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit is
recommended.
INSTALLATION CLEARANCES
36" (91.4 cm) min.
cabinet opening width
24" (61 cm) min.
30" (76.2 cm)
suggested max.
bottom of hood
to cooking surface
18" (45.7 cm)
min. clearance
upper cabinet
to countertop
36" (91.4 cm)
countertop
height
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifi cations without notice.
®
30" and 36" Range Hoods
30"(76.2 cm) or
OVERALL DIMENSIONS
5
9
"
(25.2 cm)
VENT AND ELECTRICAL OPENINGS AND MOUNTING
SCREW LOCATIONS
1 "
(3.2 cm)
1
"
(3.3 cm)
70
"
(178.6 cm)
VENTING REQUIREMENTS
min.
76
"
This range hood is factory set for vented installations. Vent system
(193.8 cm)
max.
can terminate through either the roof or a wall. The vent system
to bottom of
length should not exceed 35 ft (10.7 m)
cabinet frame
It is recommended that you use round vent instead of rectangular
vent, especially if elbows are required.
For best performance, use no more than three 90° elbows. If more
than one elbow is used, make sure that there is a minimum of 24
inches (61 cm) of straight vent between any two elbows. Do not
install two elbows together.
To calculate the length of system you need, add the equivalent
feet (meters) from chart below for each vent piece that will be
needed.
Determine the length of the vent system you need
To calculate the length of the vent system you need, add the
equivalent feet (meters) from chart below for each vent piece that
will be needed.
Recommended standard 6
1 ft. round=
1 ft. (0.3 m)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifi cations subject to change without notice.
" (14.9 cm) dia.
exhaust collar
Interchangeable
front trim
20
"
29
" (76.0 cm) - 30" (76.2 cm) model
(51.3 cm)
35
" (91.3 cm) - 36" (91.4 cm) model
Centerline of
5 "
exhaust collar
(14.9 cm)
dia.
1
"
(3.3 cm)
7 "
(19.0 cm)
Electrical
knockouts
(15.2 cm) fi ttings
"
90° elbow=
45° elbow=
5 ft. (1.5 m)
2.5 ft. (0.8 m)
9 "
(23.2 cm)
1
"
(3.0 cm)
3
"
(10.0 cm)
Centerline of
hood
Ref. 9763384
09-11-06