5. TROUBLESHOOTING
DANGER! Risk of physical injury!
Cut injury when the product starts accidentally.
v Wait for the blade to stop, remove the battery and slide the
protective cover over the blade before you troubleshoot the
product.
Problem
Possible Cause
Hedge trimmer can no
Start lever is stuck.
longer be stopped
Hedge is not cleanly cut
Blade is blunt or damaged.
Hedge trimmer vibrates
Blade is damaged.
severely
Hedge trimmer does not
Battery is empty.
start or stops.
(L1)
LED
is flashing green
[ Fig. O4 ]
Hedge trimmer does not
Battery temperature is outside
start or stops.
the permissible temperature
(Wp)
Error-LED
is illuminated
range.
red [ Fig. O4 ]
There are drops of water or
moisture between the battery
contacts on the hedge trimmer.
Engine is blocked.
Hedge trimmer does not
Product is defective.
start or stops.
Error-LED
(Wp)
is flashing
red [ Fig. O4 ]
Hedge trimmer does not
Battery is not put completely
start or stops.
into the battery holder.
Error-LED
(Wp)
is not
illuminated [ Fig. O4 ]
Battery is defective.
Product is defective.
Charging is not possible.
The battery is not connected
Battery charge indicator
(Lc)
(correctly).
is continuously illuminated
Battery contacts are dirty.
[ Fig. O3 ]
Battery temperature is outside
the permissible charging
temperature range.
Battery is defective.
Battery charge indicator
(Lc)
Mains plug of the charger is
is not illuminated [ Fig. O3 ]
not (correctly) plugged in.
Socket outlet, mains cable or
charger is defective.
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.
6. TECHNICAL DATA
Battery Hedge Trimmer
Unit
Strokes
1/min
Length of blade
cm
Tooth gap of blade
mm
Weight (without Battery)
g
Sound pressure level L
1)
dB (A)
pA
Uncertainty k
pA
Sound power level L
:
2)
WA
measured / guaranteed
dB (A)
Uncertainty k
WA
12
Remedy
v Remove the battery and
loosen the start lever.
v Let the blade be replaced by
the GARDENA Service.
v Switch off the product and
let the blade be replaced.
v Charge the battery.
v Wait until the battery tem-
perature is between
0 °C – + 45 °C again.
v Remove the water drops /
moisture with a dry cloth.
v Remove the obstacle.
Start again.
v Contact the GARDENA
Service.
v Put the battery completely
into the battery holder until
it audibly engages.
v Replace the battery.
v Contact the GARDENA
Service.
v Connect the battery to
charger correctly.
v Clean the battery contacts
(e. g. by connecting and
disconnecting the battery
several times. Replace the
battery if necessary.
v Wait until the battery
tem perature is between
0 °C – + 45 °C again.
v Replace the battery.
v Insert the mains plug into the
mains socket (completely).
v Check the mains voltage.
Let the charger be checked
if necessary by an authorised
specialist dealer or the
GARDENA Service.
Value (Art. 14733)
2400
40
16
1890
77
3.0
86 / 88
2.3
Battery Hedge Trimmer
Unit
Hand/arm vibration a
1)
m/s
2
vhw
Uncertainty k
vhw
Measuring process complying with:
62841-4-2
1)
NOTE: The stated vibration emission value has been measured according to
a standardised test procedure and can be used for comparison of one electric
power tool with another. It can also be used for preliminary evaluation of expo-
sure. The vibration emission value can vary during actual use of the electric power tool.
System Battery
Unit
PBA 18V 2.0Ah W-B
Battery voltage
V (DC)
Battery capacity
Ah
Number of cells (Li-Ion)
Appropriate POWER FOR ALL system Battery Chargers: AL 1810 CV / AL 1815 CV / AL18-20 /
AL 1830 CV / AL 1880 CV.
Battery Charger
Unit
AL 1810 CV P4A
Mains voltage
V (AC)
Mains frequency
Hz
Rated power
W
Battery charging voltage
V (DC)
Max. battery charging
mA
current
Battery charging time 80 % /
97 – 100 % (approx.)
PBA 18V 2,0Ah W-B
min.
PBA 18V 2,5Ah W-B
min.
PBA 18V 4,0Ah W-C
min.
Permitted charging
°C
temperature range
Weight according to
kg
EPTA-Procedure 01:2014
Protection class
Appropriate POWER FOR ALL system Batteries: PBA 18V.
7. ACCESSORIES
GARDENA Maintenance Oil
Extends the life of the blade and the battery idling
time.
GARDENA System Battery
Battery for additional duration or for replacement.
PBA 18V/45 P4A
PBA 18V/72 P4A
GARDENA Battery Quick
Charger for fast charging the POWER FOR ALL
Charger AL 1830 CV P4A
System Batteries PBA 18V..W-..
8. SERVICE / WARRANTY
Service:
Please contact the address on the enclosed warranty card.
Warranty statement:
The warranty is only granted according to the warranty conditions printed
on the enclosed warranty card.
Consumables:
The blade and eccentric drive are consumables and are not included in the
warranty.
Value (Art. 14733)
1.3
1.5
RL 2000/14/EC / S.I. 2001 No.1701
2)
Value (Art. 14902)
18
2.0
5
Value (Art. 14900)
220 – 240
50 – 60
26
18
1000
96 / 124
120 / 154
192 / 244
0 – 45
0.17
/ II
Art. 2366
Art. 14903
Art. 14905
Art. 14901