4.0 INSTALLATION AND ADJUSTMENT
1. Power Connection
Under normal circumstances, after the power is connected. Status
light lits red.
2. Fiber Connection
Cut off the power and take down the bolt in Fiber Input Port then
perform the following steps:
• Carefully remove the protective cap from the SC/APC connector.
• Clean the end of the connector with a lint free tissue moistened
with alcohol.
• Insert the connector into the receptacle of the SC/APC adapter.
• Power on, the status light in front panel lits green when the input
power is above -8dBm. Otherwise, it is lit red.
3. Test point
On the rear panel there is one -12dB test point.
4. Cable Connection
Connect the cables accordingly.
Important: all the input or output ports (not including the test
ports) not in use should be connected to 75Ω Ω Ω Ω Ω resistance.
5. Optical Power Monitoring
When front panel LED status light is red, it indicates that the input
optical power is lower than –8dBm. In this case, you should check
the optical link, the SC/APC connector and the output optical power
of the transmitter.
Broadata Technical Support, [email protected]
BCI 730E User's Manual
Indoor Fiber Optic CATV Receiver