Cosel AEA600F-36 Handbuch - Seite 5
Blättern Sie online oder laden Sie pdf Handbuch für Stromversorgung Cosel AEA600F-36 herunter. Cosel AEA600F-36 6 Seiten.
Derating
¿ AEA600F Derating curve depends on Input voltage
100
80
60
40
20
0
85 90
Input voltage [VAC]
¿ AEA600F Ambient temperature Derating Curve
(convection cooling)
100% Load factor in each derating curve means the rated current (convection cooling) in Specifications.
In the hatched area, the specification of Ripple and Ripple Noise are different from other area.
100
80
60
40
25
20
0
-20
-10
0
10
Ambient temperature [C]
¿ AEA600F Ambient temperature Derating Curve
(forced air cooling)
100% Load factor in each derating curve means the rated current (forced air cooling) in Specifications.
In the hatched area, the specification of Ripple and Ripple Noise are different from other area.
100
80
60
40
20
0
-20
-10
0
10
Ambient temperature [C]
¡ Forced air cooling
1 Please satisfy the below temperature at Point A and Point B under
the forced air cooling. The Point A/B position is shown in the next figure.
- Point A 90C or less and Point B 80C or less at Ta = 50C
- Point A 110C or less and Point B 100C or less at Ta = 70C
2 The forced air should be given to whole of the product.
170
264
with cover(A)
with cover(A)
(A)
(B)
with cover(B)
with cover(B)
20
30
40 45
50
60 65
70
20
30
40
50
60
70
May 25, 2021
AEA-series
Point B
T201 core
Point A
SS101
Point A
AEA-5