Align APS030-2200 Betriebshandbuch - Seite 10
Blättern Sie online oder laden Sie pdf Betriebshandbuch für Industrielle Ausrüstung Align APS030-2200 herunter. Align APS030-2200 14 Seiten. 100,000 lbs. capacity battery powered tugger
PTT6 Power Tugger
10
V. Batteries
Charging the Batteries
Always switch the battery charger off before connecting / disconnecting the battery cables.
The batteries are to be charged a minimum once a week to maintain their capacity over time.
The charging cable is to be connected to the outlet on top of the PTT6.
"Charging" is indicated by a
yellow light.
"Charge Complete" is indicated by a
green light.
The charger has an extra green light which indicates that the charging current (1 Ah) is not reached
in the maximum charging time of 20 hours to prevent overcharging and harm to the battery.