Connecting the Dishwasher
Water Connection
The dishwasher is fitted with safety devices that prevent the wash
water returning into the drinking water system and comply with the
applicable plumbing regulations.
• The dishwasher must be connected to a cold water supply.
• The dishwasher must not be connected to open hot water appliances
or instantaneous water heaters.
Permitted water pressure
Lowest permitted water pressure:
1 bar (=10 N/cm
Highest permitted water pressure:
10 bar (=100 N/cm
Connect the inlet hose
The water inlet hose must not be kinked, crushed or entangled when it
1
is being connected up.
0
Connect the threaded hose fitting (ISO 228-1:2000) on the water inlet
hose to a tap with an external thread (¾ inch). The inlet hose is
equipped either with a plastic or with a metal connection nut:
– Tighten plastic hose connection nuts by hand only.
– Metal hose connection nuts must be tightened using an
appropriate tool. Finally, visually check that it is water-tight (ensure
that the tap is not dripping).
• In order that access to the tap in the kitchen is not limited by the use
3
of the dishwasher, we recommend the installation of an additional
tap, or fitting a two way adapter to the existing tap.
• If you need a longer water inlet hose than that supplied, VDE
approved complete hose sets are to be used. These are available from
your local Service Force Centre.
• Do not use, for connection, old hoses which have been used for
another appliance.
2
=100 kPa)
2
=1 MPa)
Installation and Connection Instructions
Consult your installer if the water pres-
sure is less than 1 bar.
In the case of a water pressure greater
than 10 bar, a pressure reduction valve
must be used (available from your
dealer).