Fujitsu 12RLFCD Handbuch - Seite 21

Blättern Sie online oder laden Sie pdf Handbuch für Klimagerät Fujitsu 12RLFCD herunter. Fujitsu 12RLFCD 48 Seiten. Mini-split air conditioners and heat pumps

Fujitsu 12RLFCD Handbuch
Wall Mounted 30,000 BTU Systems
SYSTEM 30RLX
Function
This wall mounted heat pump provides both heating and
cooling for year-round comfort. Ultra compact yet
7
efficient, System 30RLX provides maximum comfort in
30% less space while saving you money. Additionally,
6
System 30RLX provides low ambient operation rated down
to 0°F right out of the box without modification.
Standard Features
Wireless Remote Control
POWERFUL
W
ireless
Apple Catechin Filter
POWERFUL
Ion Deoderizing Filter
Sleep Timer
24-Hour Timer
24 Hour
6
Weekly Timer*
7
7
Dry Mode
D
ry
6
6
Auto Louver: 4-way
POWERFUL
Auto Mode
50 F
Minimum Heat Mode
7
* Available only with optional wired remote controller.
6
**Operation monitoring and On/Off control only.
POWERFUL
POWERFUL
Optional Wired Remote
POWERFUL
Weekly Timer
Full Function Wired Remote
Child Lock Capable
Easy Maintenance
Front panel is easily
removed for cleaning.
Applications
Fujitsu ductless heat pumps can be used to solve
various application-specific problems. Businesses and
institutions such as schools, churches, nursing homes
and hospitals, commercial office buildings, strip malls,
motels and restaurants, apartments and condos,
computer and telephone switching rooms, and even
residences commonly use these systems. With more
efficient zone control, "ductless mini-splits" are perfect
for renovations, restorations, conversions, and add-ons.
7
6
Economy Mode
POWERFUL
Quiet Mode
7
7
Power Diffuser
6
D
iffuser
6
Auto Restart/Reset
7
Auto Changeover
7
7
0°F
0°F Ambient Cooling
6
A
mbient
6
165 ft
Long Piping Length
P
iping
Cold Prevention
C
old
Pump Down Operation
P
D
ump
own
I/O
3
rd
Party Device Control**
POWERFUL
3
rd
P
arty
7
POWERFUL
6
UTY-RNBYU
(Indoor)
17.5 SEER
Nominal Cooling
BTU/h
Min.~Max. Cooling
BTU/h
Nominal Heating
BTU/h
Min.~Max. Heating
BTU/h
HSPF
BTU/hW
SEER
BTU/hW
EER
Clg/Htg
Clg. Operating Range °F(°C)
Htg. Operating Range °F(°C)
Moisture Removal
Pt./h(l/h)
Voltage/Frequency/Phase
Recommended Fuse Size
(A)
Air Circ.
: Hi
C.F.M. (m
/h)
3
677 (1,150) Htg
Medium
Low
Quiet
Noise Level
: Hi
dB(A)
Medium
Low
Quiet
Outdoor Fan Speed RPM Clg/Htg
Outdoor Noise Level
dB(A)
Current
: Cooling
(A)
Rated/Max
Heating
Power Use
(kw): Cooling
Rated/Max
Heating
Fan Speeds Stage
Air Direction: Horizontal
Vertical
Air Filter
ENERGY STAR
®
Qualified
Connection Method
Combined Min. Lgth
Ft (m)
Combined Max. Lgth
Ft (m)
Max. Vertical Diff.
Ft (m)
Conn. Pipe Diameter
Suc. 5/8
Inch
Net Weight lbs.
31 (14)
(kg)
Dimensions: Height
12-5/8
Inch
mm
Width
39-1/4
Inch
mm
Depth
Inch
mm
Refrigerant
Note: Figures are based on 230 Volts.
30RLX
Heat Pump
30,000
9,900~32,400
32,000
8,000~37,500
9.5
17.5
10.0
0~115 (-18~46)
0~75 (-18~24)
9.5 (4.5)
208-230/60/1
30
659 (1,120) Clg
530 (900)
435 (740)
365 (620)
49/49
(Clg/Htg)
42/42
(Clg/Htg)
37/37
(Clg/Htg)
33/33
(Clg/Htg)
850/850
54/55
(Clg/Htg)
13.2/17.0
13.1/18.5
3.0/3.87
2.99/4.22
4 + Auto
Automatic
Automatic
Washable
No
Flare
16 (5)
164 (50)
(pre-charge: 66')
98 (30)
Dis. 3/8
135 (61)
32-3/4
320
830
35-3/8
998
900
9
13
228
330
R410A
21