Fujitsu ABT24UB Betriebshandbuch - Seite 10

Blättern Sie online oder laden Sie pdf Betriebshandbuch für Klimagerät Fujitsu ABT24UB herunter. Fujitsu ABT24UB 20 Seiten. Floor console/under ceiling dual type
Auch für Fujitsu ABT24UB: Betriebshandbuch (20 seiten)

Fujitsu ABT24UB Betriebshandbuch

SLEEP TIMER OPERATION

Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.
To Use the SLEEP timer
While the air conditioner is operating or stopped, press the
SLEEP button.
Both the indoor unit's OPERATION indicator lamp (red) and the TIMER indicator
lamp (green) will light.
To Change the Timer Settings
Press the SLEEP button once again and set the time using the
SET TIME buttons.
Set the time while the Timer Mode Display is flashing (the flashing will continue for
about five seconds).
button: Press to advance the time.
button: Press to reverse the time.
About five seconds later, the entire display will reappear.
About the SLEEP timer
To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifies the thermostat setting
in accordance with the time setting. When the set time has elapsed, the air conditioner completely stops.
During Heating operation (HEAT & COOL MODEL (Reverse
cycle) only):
When the SLEEP timer is set, the thermostat setting is
automatically lowered 1 °C every thirty minutes. When the
thermostat has been lowered a total of 4 °C, the thermostat
setting at that time is maintained until the set time has elapsed,
at which time the air conditioner automatically turns off.
SLEEP timer setting
30
minutes
1 hour
1 hour
30 minutes

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote control unit is lost or otherwise unavailable.
How To Use the Main Unit Controls
Press the MANUAL AUTO button on the main unit control
panel.
To stop operation, press the MANUAL AUTO button once again.
9
1 °C
2 °C
3 °C
4 °C
Set time
To Cancel the Timer:
Use the TIMER button to select "TIMER
RESET".
The air conditioner will return to normal
operation.
To Stop the Air Conditioner During
Timer Operation:
Press the START/STOP button.
During Cooling/Dry operation:
When the SLEEP timer is set, the thermostat setting is auto-
matically raised 1 °C every sixty minutes. When the thermo-
stat has been raised a total of 2 °C, the thermostat setting at
that time is maintained until the set time has elapsed, at which
time the air conditioner automatically turns off.
SLEEP timer setting
CAUTION!
Do not press the MANUAL AUTO button with
wet hands or pointed objects, otherwise an
electric shock or malfunction may occur.
● When the air conditioner is operated
with the controls on the Main unit, it
will operate under the same mode as
the AUTO mode selected on the re-
mote control unit (see page 7).
● The fan speed selected will be "AUTO"
and the thermostat setting will be
23 °C.
Set time
1 hour
2 °C
1 °C