Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation and Use)
Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition).
Detailed recommendations are contained in the following British Standards Codes Of
Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions.
The hob should not be installed in a bed sitting room with a volume of less than 20 m
.
3
If it is installed in a room of volume less than 5 m
an air vent of effective area of 110 cm
3
2
is required. If it is installed in a room of volume between 5 m
and 10 m
an air vent of
3
3
effective area of 50 cm
is required, while if the volume exceeds 11 m
no air vent is
2
3
required.
However, if the room has a door which opens directly to the outside no air vent is required
even if the volume is between 5 m
and 11 m
.
3
3
If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current
Edition, should be consulted to determine the requisite air vent requirements.
Location
The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a
bathroom or shower room.
Before making the cut out in the worktop ensure that there is a minimum distance of 55
mm. between the rear edge of the hob and the wall.
A minimum distance of 100 mm. must be left between the side edges of the hob and any
adjacent cabinets or walls.
The minimum distance combustible material can be fitted above the hob in line with the
edges of the hob is 420 mm. If it is fitted below 420 mm. a space of 50 mm. must be
allowed from the edges of the hob.
The minimum distance combustible material can be fitted directly above the hob is 700
mm.