Blättern Sie online oder laden Sie pdf Betriebsanleitung für Kochfeld AEG 79902 herunter. AEG 79902 44 Seiten. Electronic gas hob
Conversion to LPG
Replacing the injectors
1. Remove the pan supports.
2. Remove the burner caps and crowns.
3. Using a 7 mm socket spanner
remove the
injectors,
with the ones required for the new type
of
gas
(see the table "Burner
characteristics").
Reassemble the parts, following the
4.
same procedure backwards.
5. Replace the Gas Type Label (located near
the gas supply connection) with the one
corresponding to the new type of gas. The
label is supplied in the accessories plastic
bag.
Should the feeding gas pressure be different or
variable compared with the required pressure,
an appropriate pressure regulator must be fitted
on the gas supply pipe, in compliance with the
rules in force.
Burner characteristics
GAS
BURNER
TYPE
TYPE
NATURAL
Rapid
GAS
Semirapid
( G 2 0 )
Auxiliary
LIQUID
Rapid
GAS
Semirapid
(Butane/
Auxiliary
Propane)
unscrew and
then replace them
INJECTOR
NOMINAL
REFERENCE
THERMAL
1/100 mm
POWER
119
96
70
86
71
50
REDUCED
THERMAL
POWER
kW
kW
2.9
0.65
1.9
0.45
1.0
0.33
2.7
0.65
1.9
0.45
1.0
0.33
NOMINAL
FEEDING
FLOW RATE
PRESSURE
m 3 /h
g/h
mbar
0.276
0.181
-
0.095
-
-
196
-
138
28-30/37
-
73
20
33