Symptom
Paper frequently multi
feeds.
Paper does not feed
(pick error occurs fre-
quently, or document
stops midway).
Are the scanned images
elongated?
Is there a shadow on the
top or bottom edge of
the scanned image?
Check this item
Have the document requirements
of the fi-5110C Operator's Guide's
"Document Quality" and the "multi
feed Detection Conditions" of chap-
ter 7 been satisfied?
Are the documents placed properly
in the ADF paper chute?
Is the stack of document thicker
than 5 mm?
Is the Pad ASSY dirty?
Is the Pad ASSY worn out?
Have the document requirements
of the fi-5110C Operator's Guide's
"Document Quality" and the "Multi
Feed Detection Conditions" of
chapter 7 been satisfied?
Is the Pick roller dirty?
Is the Pick roller worn out?
Is there any dirt or dust in the docu-
ment feed path?
Are the Feed rollers dirty?
Have you adjusted the scan scale?
Are the Feed rollers dirty?
Is the offset adjusted?
fi-5110C Image Scanner Getting Started
Remedy
Use document conditions that meet the
"Document Quality" and the "Multi Feed
Detection Conditions" in chapter 7 of the fi-
5110C Operator's Guide.
Fan the documents before scanning. Cor-
rectly align the document stack and load
them on the ADF paper chute. Refer to "2.2
Installing the Scanner" on page 9 for
details.
Reduce the number of sheets of the stack
to a thickness of 5 mm or less.
Clean the Pad ASSY. Refer to Operator's
Guide in "Chapter 4 Daily Care".
Replace the Pad ASSY. Refer to Opera-
tor's Guide in "5.2. Replacing the Pad
ASSY".
Use document conditions that meet the
"Document Quality" and the "Multi Feed
Detection Conditions" in the chapter 7 of
the fi-5110C Operator's Guide.
To clean the pick roller, refer to Operator's
Guide in "Chapter 4 Daily Care".
Change the Pick roller. Refer to Operator's
Guide in "5.3. Replacing the Pick Roller".
Remove any dirt or dust from the docu-
ment feed path.
Clean the Feed rollers. Refer to Operator's
Guide in "Chapter 4 Daily Care".
Select "Scanners and Cameras" in the con-
trol panel, then click the [Device Set] tab to
adjust scale.
Clean the Feed rollers. Refer to Operator's
Guide in "Chapter 4 Daily Care".
On [Scanners and Cameras] in the control
panel, adjust the [Sub-scan Setting] (in
case there is a shadow in the top edge) or
adjust the [Bottom] (in case there is a
shadow in the bottom edge).
AP-2