Fujitsu eternus af Konfigurationshandbuch - Seite 25
Blättern Sie online oder laden Sie pdf Konfigurationshandbuch für Lagerung Fujitsu eternus af herunter. Fujitsu eternus af 28 Seiten. Fibre channel for citrix xenserver
Auch für Fujitsu eternus af: Konfigurationshandbuch (25 seiten), Konfigurationshandbuch (32 seiten), Konfigurationshandbuch (43 seiten)
Chapter 9
Setting the Multipaths
9.3
Reconfiguring and Restarting the Server
Otherwise, add this line or change its value to "enable".
# Copyright 2004 Sun Microsystems, Inc.
All rights reserved.
# Use is subject to license terms.
#
#pragma ident "@(#)scsi_vhci.conf 1.9 04/08/26 SMI"
#
name="scsi_vhci" class="root";
#
# Load balancing global configuration: setting load-balance="none" will cause
# all I/O to a given device (which supports multipath I/O) to occur via one
# path. Setting load-balance="round-robin" will cause each path to the device
# to be used in turn.
#
load-balance="round-robin";
#
# Automatic failback configuration
# possible values are auto-failback="enable" or auto-failback="disable"
auto-failback="enable";
#
# For enabling MPxIO support for 3rd party symmetric device need an
# entry similar to following in this file. Just replace the "SUN SENA"
# part with the Vendor ID/Product ID for the device, exactly as reported by
# Inquiry cmd.
#
# device-type-scsi-options-list =
# "SUN SENA", "symmetric-option";
#
# symmetric-option = 0x1000000;
Check that "round-robin" is set for (1).
Check that "enable" is set for (2).
9.3
Reconfiguring and Restarting the Server
Reconfigure and restart the server to effect the new settings.
# touch /reconfigure
# /usr/sbin/shutdown -y -g0 -i6
Use the "format" command to check the MPxIO multipath status after multipathing is set up.
Example: ETERNUS DX80
# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c2t0d0 <FUJITSU-MAW3073NCSUN72G-1703 cyl 14087 alt 2 hd 24 sec 424>
/pci@1f,700000/scsi@2/sd@0,0
1. c5t600000E00D0000000000100101440000d0 <FUJITSU- ETERNUS_DXL-0000 cyl 510 alt 2 hd 64 sec 256>
/scsi_vhci/ssd@g600000e00d0000000000100101440000
2. c5t600000E00D0000000000100101430000d0 <FUJITSU- ETERNUS_DXL-0000 cyl 510 alt 2 hd 64 sec 256>
/scsi_vhci/ssd@g600000e00d0000000000100101430000
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (iSCSI) for Oracle Solaris
f (1)
f (2)
25
Copyright 2017 FUJITSU LIMITED
P3AM-4042-18ENZ0