Chapter 2
Basic Operation
2.1
Powering On and Off
1
Press the Power switch of the ETERNUS DX.
Power switch
The POWER LED on the ETERNUS DX is turned on.
2
After approximately two minutes, check that the READY LED of the ETERNUS DX is lit up.
2.1.3

Powering Off

To turn off the ETERNUS DX, perform one of the procedures below.
Via power switch
Press the Power switch to turn off the ETERNUS DX.
Via ETERNUS Web GUI or ETERNUS CLI
Use ETERNUS Web GUI or ETERNUS CLI to turn off the ETERNUS DX.
The following methods can be used to turn the power off remotely.
Via the power synchronized unit
Use the power synchronized unit to turn off the ETERNUS DX.
When turning off the ETERNUS DX, the power shuts off after the write data in the cache memory is writ-
ten back to the drives. As a result, it may take approximately one minute or up to six minutes maximum
for the power supply to be completely turned off.
Do not turn off the power of the ETERNUS DX and the network devices that connect the ETERNUS DX to a
server while the server is operating. This may result in the loss of data or prevent data from being saved
in the ETERNUS DX.
When using a power synchronized unit for power control, turn off the power of the ETERNUS DX via the
power synchronized unit. When a power synchronized unit is connected, the power of the ETERNUS DX is
automatically turned on because the power synchronization function is activated.
After power-off, wait for about one minute before turning power on again.
This section explains how to use the Power switch to turn off the ETERNUS DX.
For other procedures, refer to the related manuals.