Chapter 2
LT140 Installation
This chapter describes the installation specifications and the installation environment.
2.1
Installation Specifications
The following table shows the installation specifications of the LT140.
Table 2.1
Installation specifications
Module
Tape drive
External
dimensions
Weight (*2)
Power
Maximum power consumption
Maximum heat generation
Environmental
conditions
*1:
The Expansion Module can be increased to one Base Module up to six.
*2:
For Base Modules, the value is for redundant PSU configurations. Excludes the weight of media and tape drives.
For Expansion Modules, the value when PSUs are not installed. Excludes the weight of media and tape drives.
A single drive is approximately 2 kg and a single PSU is approximately 1 kg.
FUJITSU Storage ETERNUS LT140 Tape Library User's Guide -Site Planning-
Item
Max number installed
Height
Width
Depth
Voltage
Number of phases
Frequency
AC input sources
Operating
Temperature
In transport
Operating
Humidity
In transport
Altitude above sea level
Dust concentration
17
Copyright 2018 FUJITSU LIMITED
Spec
Base Module
Expansion Module (*1)
3
132 mm (3U)
475 mm
892 mm
22 kg
100 - 240 V
Single
50/60 Hz
1 (standard) or
2 (redundant)
118W (147.5VA)
424.8kJ/h
10 to 35° C
-40 to 60° C (excluding media)
20 to 80% RH
10 to 80% RH (excluding media)
5000 meters (16,450 feet)
Less than 200 microgram / cubic meter
14 kg
0 (standard) or
1 – 2 (redundant)
90W (112.5VA)
324.0kJ/h
P3AG-3712-01ENZ0