Chapter 2
2.1

Common Settings

This section explains the settings required for all server OSes, regardless of the connection con-
figuration. For details of how to use ETERNUSmgr to perform these settings, refer to the
"ETERNUSmgr User Guide".
2.1.1
Setting the To-server Connection Type (Setting the CA Parameters)
For each connection configuration, perform the following iSCSI port parameter settings only. All
other parameters should be left on their default values.
Table 2.1
TCP/IP Setting
iSCSI Settings
Security
P3AM-4172-02ENZ0
Server Connection Guide (iSCSI) ETERNUS Disk Storage System Settings
ETERNUS Disk Storage System
Connection Settings
CA parameter settings (iSCSI port settings)
Parameter
IP Address
Subnet Mask
Gateway
iSNS Server
iSCSI Name
Alias Name
CHAP
User Name
New Password
New Password (Re-enter)
Solaris OS, HP-UX, Windows®, Linux, VMware ESX
Arbitrary
Arbitrary
Arbitrary
Select "ON" to use the iSNS server, and specify the IP
address for the iSNS server.
Arbitrary
Caution:
When configuring multipaths, specify a different name for
each iSCSI port.
If the same iSCSI name is specified for multiple ports,
connection via multipaths may not be available.
Arbitrary
OFF (Default value): When both unidirectional CHAP
authentication and bidirectional CHAP authentication are not
used
ON: When either unidirectional CHAP authentication or
bidirectional CHAP authentication is used
When using bidirectional CHAP authentication, set a pass-
word.
When using unidirectional CHAP authentication, a CHAP
user name and password do not need to be set.
11
Copyright 2010 FUJITSU LIMITED