Your refrigerator needs air
The refrigerating unit of your refrigerator is designed for maintenan-
ce-free operation. What it should never lack is good ventilation. Air is
supplied under the door through the ventilation slot between the ref-
rigerator an storage surface. Air is extracted through the upper venti-
lation grille. Never obstruct these openings by plinth screens or
crockery.
If your refrigerator is installed under a
continuous worktop, an air outlet
opening of at least 200 cm 2 and a
ventilation grille (A/B) matching the
worktop design should be provided at
the rear of the worktop. The cut sur-
faces of the worktop (C) should be
varnished to avoid swelling due to
penetration of moisture.
The appliance wall distance must be
at least 30 mm and should be checked
before the ventilation grille is inserted.
Special accessories:
A Ventilation grille, brown
B Ventilation grille, white
Detaching the worktop
After the worktop has been removed the appliance can be installed
underneatch a continuous worktop.
The procedure is as follows:
Unscrew the Phillips screws (F) on the
right and the left.
Lift the work-top slightly, push it
about 20 mm towards the rear, and
lift it off upwards (G).
Unscrew the holding bracket (H) and
keep it in a safe place.
A/B
105
570
550
AEG36
F
G
AEG56
2
200 cm
C
93-103
H
47