Fujitsu D3031 Technisches Handbuch - Seite 31

Blättern Sie online oder laden Sie pdf Technisches Handbuch für Hauptplatine Fujitsu D3031 herunter. Fujitsu D3031 38 Seiten. System board for primergy rx200 s6

Fujitsu D3031 Technisches Handbuch
Features
No.
Description
1
CSS indicate button
LEDs A, B and C are visible from outside on the rear of the server. All the other
LEDs are only visible, if the cover of the server has been opened.
If the server has been powered off (power-plugs must be disconnected) it is
possible to indicate the faulty component by pressing the CSS indicate button.
The LEDs have the following meaning:
LED
A - GEL
(Global Error
LED)
B - CSS
(Customer Self
Service)
C - Identification blue on
D - Controller
E - CPU
F - system fans
G - memory
H - iRMC S2
D3031 (RX200 S6)
Indicator
Meaning
orange on
indicates a prefailure
orange flashing indicates a failure. Reasons for a failure
may be:
– a sensor detects an error
– sensor defect
– fan defect
– CPU
– Software detected an error
yellow on
indicates a prefailure
yellow flashing indicates a failure
server is identified via the ServerView
Operations Manager
orange on
controller failure
orange on
CPU failure
green on
fan okay
orange on
fan failure
orange on
memory module failure
green flashing
iRMC S2 okay
Technical Manual
Connectors and indicators
e rror
31