4.7 Analogue Power Supply Voltage (JP: 11, 13, 15)

The power supply as well as the positive reference voltage for the A/D-converter can be
provided internally or externally.
JP11, JP15 connects analog power supply voltages (AVcc and AVss)
JP13
connects the low pass filtered analog reference voltage AVRH to AVcc
Jumper
JP11 (AVcc)
JP13 (AVRH)
JP15 (AVss)
Rule 5: By default, the A/D-converter supply and reference voltage is the same as
the microcontroller supply voltage.
Note:
If JP11 and J15 are open, the user has to supply an adequate analogue voltage
supply (AVcc and AVss) to the A/D-converter.
If JP13 is open, the resistors R11 and R23 define AVRH.
By default the resistor network (R11 and R23) is not mounted on the board.
© Fujitsu Semiconductor Europe GmbH
SK-96620_350-64PMC(1) User Guide
Chapter 4 Jumpers and Switches
Setting
Description
Closed
AVcc is connected to Vcc
Open
AVcc is disconnected from Vcc
Closed
AVRH is connected to AVcc
Open
AVRH defined by resistor network
Closed
AVss is connected to GND
Open
AVss is disconnected from GND
Table 4-6: ADC Supply Settings
- 22 -
*1
UG-960028-12