THE MC1000 KEYPAD
STOP
> 20.00 HZ
PROG
AUTO
RUN
MAN
FWD
ENTER
REV
PROGRAMMING THE MC1000 DRIVE
1. Press the PROG/RUN key. This will cause the PASSWORD prompt
to appear (unless the password protection has been disabled), as
shown below:
PASSWORD
0000
2. Use the
and
keys to scroll to the correct password value
(the factory default password is 0019) and press ENTER. The
PROGRAM mode will be entered at the start of the parameter
menu. A cursor will highlight the parameter name.
3. Use the
and
keys to scroll to the desired parameter and
press ENTER. The cursor will shift from the parameter name
to the parameter value, as the example below illustrates:
ACCEL
30.0 SEC
CURSOR
ENTER
4. Use the
and
keys to scroll to the desired parameter value,
and press ENTER to store the new value.
5. Press PROG/RUN to exit the PROGRAM mode.
MC1000 KEYPAD FUNCTIONS
START
STOP
START
STOP
FWD
REV
CURSOR
AUTO
MAN
PROG
RUN
ENTER
Press the START key to start the drive. The START
key is only active in LOCAL mode.
Press the STOP key to stop the drive.
NOTE: The STOP key is active in both LOCAL and
REMOTE mode.
The STOP key is also used to reset faults. If the fault
condition has passed, pressing the STOP key will clear
the fault and return the drive to a STOP condition.
UP and DOWN ARROWS - Used to change the speed
setpoint in MANUAL mode, scroll through the
parameter menu, and change parameter values.
Toggles between FORWARD and REVERSE rotation.
NOTE: Parameter 27 - ROTATION must be set to FWD
& REV, and the drive must be in LOCAL mode for this
key to be active.
Toggles between AUTOMATIC (terminal strip) and
MANUAL (keypad) speed control.
NOTE: Parameter 28 - AUTO/MAN must be set to
BOTH for this key to be active.
Used to enter and exit the PROGRAM mode to set the
parameters.
Used for: toggling the display between SPEED, LOAD,
and MOTOR VOLTAGE; confirming new parameter
values; confirming AUTO and MANUAL speed control
selections; confirming LOCAL and REMOTE start/stop
mode selections.
Press and hold the ENTER key to activate the
AUXILIARY MODE, which consists of two displays
that cycle in one second intervals. One indicates
LOCAL/REMOTE mode, AUTO/MANUAL mode, and
the speed reference source, and the other is an elapsed
time meter that indicates total run time.
MC1000 DISPLAYS
Shown below are examples of MC1000 displays. To scroll through the
SPEED, LOAD, and MOTOR VOLTAGE displays, press and release
the ENTER key.
DRIVE
STATUS
SPEED DISPLAY
RUN
ROTATION DIRECTION
(">" = Forward, "<" = Reverse)
ENTER
DRIVE
STATUS
LOAD DISPLAY
RUN
ENTER
DRIVE
STATUS
MOTOR VOLTAGE
RUN
DISPLAY
Press and hold the ENTER key to activate the AUXILIARY MODE
display, which indicates the control source (LOCAL, REMOTE, or
SERIAL), AUTO or MANUAL mode, and the speed reference source.
An example is shown below (IDC = 4-20 mA signal):
PRESS
& HOLD
CONTROL
AUTO/MAN
ENTER
SOURCE
AUXILIARY MODE
LOCAL -- AUTO -- IDC
DISPLAY
SPEED
SPEED
SETPOINT
UNITS
>
60.00 HZ
PERCENT
LOAD
> 85% LOAD
MOTOR
VOLTAGE
>
460 VAC
SPEED
REFERENCE
MODE
SOURCE