Indesit I5GG Betriebsanleitung - Seite 7
Blättern Sie online oder laden Sie pdf Betriebsanleitung für Herde Indesit I5GG herunter. Indesit I5GG 16 Seiten.
Table of burner and nozzle specifications
Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
51
(Small)(A)
Oven
-
Grill
-
Supply
Pressures
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
S S
A
R
I5GG/UK
I5GG1/UK
Thermal Power
By-Pass
kW (p.c.s.*)
Nominal
Reduced
3.00
0.7
1.90
0.4
1.00
0.4
2.80
1.0
2.30
-
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
3
Liquid Gas
Nozzle
Flow*
1/100
1/100
(mm)
(mm)
***
41
87
218
30
69
138
30
50
73
46
80
204
-
75
167
28-30
20
35
TECHNICAL DATA
Oven dimensions
(HxWxD)
Volume
Useful
measurements
relating to the oven
compartment
Power supply voltage
and frequency
Burners
Natural Gas
Nozzle
Flow*
g/h
1/100
l/h
**
(mm)
214
128
286
136
104
181
71
78
95
200
119
267
164
114
219
37
20
25
17
45
25
34x39x44 cm
58 l
width 42 cm
depth 44 cm
height 17 cm
see data plate
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments - 2002/96/EC.
1275/2008 (Stand-by/ Off mode)
GB
7