Installation
! Please keep this instruction booklet in a safe place for
future reference.. Make sure the booklet remains with
the appliance if it is sold, given away or moved.
! Please read this manual carefully: it contains
important information on installation, operation and
safety.
! The appliance must be installed by a qualified
professional in accordance with the instructions
provided.
! Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected
from the electricity supply.
Positioning and levelling
! The appliance may be installed alongside any
cupboards whose height does not exceed that of the
hob surface.
! Make sure that the wall which is in contact with the
back of the appliance is made from a non-flammable,
heat-resistant material (T 90°C).
To install the appliance correctly:
• Place it in the kitchen, the dining room or the studio
flat (not in the bathroom).
• If the top of the hob is higher than the cupboards,
the appliance must be installed at least 600 mm away
from them.
• If the cooker is installed underneath a wall cabinet,
there must be a minimum distance of 420 mm
between this cabinet and the top of the hob.
HOOD
600
Min.
mm.
with the instructions listed in the relevant operating
manual.
* Only available in certain models.
This distance should be
increased to 700 mm
if the wall cabinets are
flammable (see fi gure).
Do not position
blinds behind the cooker
or less than 200 mm
away from its sides.
Any hoods must be
installed in accordance
Levelling
If it is necessary to level the
appliance, screw the adjustable
feet into the positions provided
on each corner of the base of
the cooker (see fi gure).
The legs* fit into the slots on the
underside of the base of the
cooker.
Electrical connection
Fitting the power supply cable
To open the terminal board:
• Insert a screwdriver into the side tabs of the terminal
board cover.
• Pull the cover to open it.
below:
• Loosen the cable clamp screw and the wire contact
screws.
! The jumpers are pre-set at the Factory for 230 V
single-phase connection (see fi gure).
230V ~
H05RR-F 3x4 CEI-UNEL 35363
H05VV-F 3x4 CEI-UNEL 35746
N
L
• To carry out the electrical connections as shown in
the figures, use the two jumpers inside the box (see
fi gure - labelled "P").
To install the cable,
follow the instructions
11