Cold accumulation block
There is one cold accumulation block in the freezer tray.
Refer to the section "Prior to Initial Start–Up" concerning freezing of
the cold accumulation block.
In the event of a power failure or malfunction, the cold accumulation
3
block will increase the hold over period by several hours, providing
it is placed in the uppermost drawer, at the front, above the frozen
food.
You can also use the cold accumulation block in a cool bag.
Prior to Initial Start–Up
Before connecting the appliance to the mains and putting it into ope-
1
ration for the first time, leave the appliance to stand for 30 minutes if
was transported upright. After transport on its side, the appliance must
be left to stand for 4 hours before putting it into operation. This is
necessary to allow the refrigerant to flow back into the compressor.
Otherwise the compressor may be damaged.
0 Please clean the appliance interior and all accessories prior to initial
start-up (see section: "Maintenance and Cleaning").
0 Remove the cold accumulation block from the appliance.
0 Only put the cold accumulation block to freeze in the top compartment
after the optimal storage temperature of –18 °C has been reached.
0 After 24 hours place the cold accumulation block in the uppermost
compartment, at the front, above the frozen food.
0 Re-freeze the thawed cold accumulation block in the same way, e. g.
after cleaning the appliance.
16